KEEP YOUR DaSPENSUNG
RESERVOIR (TANK) SOLUTION LEVEL
NOTE: Be sure to check the chlorine residual
and/or pH level every few days to keep the readings within the limits.
REMOVING AND CLEANING THE PUMP HEAD
CARTRIDGE VALVES
1.Remove suction, discharge and return to supply valves from the head_
NOTE: Plug tubing (use pencil or other tool) to pre- vent loss of solution.
2.Place valves in a container filled with vinegar and soak for about 15 minutes
3.Thoroughly flush with fresh faucet water,,
CHECKING THE PUMP HEAD CARTRIDGE VALVES
1.Remove the solution tank cover°
2.Open a faucet to start the well pump and solution pump,,
3.Look into the tank to see if solution is returning to the tank through the top bulkhead fitting. If solu- tion is returning ....
. .a_ Injection fitting plugged, or water system _ressure over 100 psL
o .b.
4. Open the
only). If solution does not return to the tank ......
. ,a. Suction valve leaking or plugged,
•..b, Return to supply valve is leaking.
5.Open the
•..a. Discharge valve is leaking.
6.Close the
4.Visually inspect and repeat steps 2 and 3 if needed.
5.Put some silicone grease or vaseline on the threads of the fitting_ Then install in the correct position in the pump head° Finger tighten, then turn another 1/8 to 1/4 turn with a pliers°
6, Connect the tubing to the fitting using the holding nuL Refer to FIG 1, page 6 for correct hookup,
SUCTION VALVE
Fitting
take apart here
Seat
Spring Ball
DISCHARGE & RETURN TO SUPPLY VALVES
take apart here | Fitting |
7.Remove and clean or replace valves or the injec- tion fitting,
Ball Spring
15