Sears 625.34929 owner manual Where To Locate Your, PiCK THE BEST WAY TO INJEI, the system where

Models: 625.34929

1 20
Download 20 pages 29 Kb
Page 7
Image 7
WHERE TO LOCATE YOUR

WHERE TO LOCATE YOUR

Locate

the system where...

 

.... IT'S AWAY

FROM

DIRECT SUNLIGHT

......a

115

volt, 60

Hz

electrical power source is

A

DAMAGE

FROM

SOLUTIONS,

DUE TO

nearby.

(See

page

11)

 

LEAKS THAT COU

LD OCCUR,

IS LEAST

 

 

 

 

 

 

LIKELY

 

 

 

...good fresh air flow will cool the solution pump motor and carry away solution fumes.

..... the area is clean and the air is free of dust.

A _ .the solution pump and tank are easy to

reach for servicing and refilling, BUT OUT OF THE REACH OF CHILDREN

it's close to the solution injection point Read about the 3 ways to inject solution, below.

PiCK THE BEST WAY TO INJEI

Chlorine or neutralizer feeding is done in 1 of 3

ways with the solution dispensing system Read the following and pick the best way to treat your water supply..

(# Chlorine or neutralizer injected right into the well casing (FIG. 2, below and FIG. 4, page 8) - This is the best way to feed chlorine.

(_) Chlorine or neutralizer injected into the alternate discharge fitting on the well pump

(FIG. 2 and FIG. 5, page 9)-This is the best way to feed neutralizer.

(_) Chlorine or neutralizer injected at some point between the well pump and pressure tank (FIG. 2 and FIG 6, page 10).

IMPORTANT: When the well pump is running, the solution feed pump is feeding chlorine or

neutralizer into the water.. For the chlorine or

neutralizer to work right, it must mix with the problem water for a short time. With today's fast recovery water pumps and direct fresh

water drawing, most water bypasses the

pressure tank.. This does not allow enough time for good solution mixing to treat the pro- blem water. If you have a fast water pumping system*, you must install a 42 gallon (or larger) blending tank, as shown in FIG. 3, to get the needed mixing time. A blending tank is avail-

able from Sears, Stock No. 42.34028o

NOTE: In 90 to 95% of all Solution Dispensing

System installations, a blending tank is needed for proper Solution mixing° A blending tank is

helpful in all installations, but in some (shallow well, long piping runs, feeding neutralizer com- pound only) it could be left out under certain

conditions° Talk to your Sears sales depart- ment for help.

To Household

ULC )

Water

Pressure

Filter

Tank

 

I From Well

 

I

(_ SOLUTION INJECTION INTO THE

WELL CASING-- PAGE 8

(_) SOLUTION INJECTION INTO THE

WELL PUMP ALTERNATE DIS- CHARGE FITTING -- PAGE 9

(_) SOLUTION INJECTION BETWEEN THE WELL PUMP AND PRESSURE

TANK-- PAGE 10

CAUTION: CHLORINE, INJECTED INTO THE WATER, MAY SHORTEN THE LIFE OF GASKETS AND SEALS IN YOUR WATER SYSTEM

7