ELECTRICAL WgRRNGGUIDE, €
A CAUTION: DO NOT TRY TO DO ANY WIRING IF YOU DO NOT KNOW ELEC-
TRICITY. CALL A GOOD ELECTRICIAN
A CAUTION: DO NOT DO ANY WIRING ON
LIVE CIRCUITS ALWAYS TURN OFF THE
ELECTRICAL POWER AT THE SOURCE,
NOTE: All wiring must follow local or national electrical codes.
1. Looking at FIG.7and8or9, installand wire
in a duplex,
"outlet Be sure to connect the outlet through the well pump pressure switch so the solution pump runs only when the well pump is on
,_ CAUTION: Many well pumps work on 230 volts. DO NOT CONNECT THE SOLUTION
PUMP TOA230VOLTCIRCUIT, Connectto only 1 leg of a single phase 230 volt circuit, as shown in FIG 9.
2, Turn on the electrical power at the source DO NOT plug in the power cord this time. First, fill the storage tank with solution (page 12).
115 VOLT OUTLET
Wall
Receptacle
Conduit
WIRING DIAGRAM - 115 VOLT SYSTEM
Duplex. | Solution | |
Electrical | Outlet | Pump |
Well | n Pump |
Pump | Power Cord |
From
115V Power
Source
_'N Pump
Pressure
Switch
115V
WIRING DIAGRAM - 230 VOLT SYSTEM
Solution Pump Solution
Power Cord Pump
L 1 Star | Neutral |
|
| L1 | 230V |
| L2 | Power |
|
| Souse |
| 230V |
|
Well | Control |
|
Box |
| |
Pump |
| |
or |
| |
|
| |
| Pressure |
|
| Switch |
|
11