ERROR MESSAGES

When an error message is displayed, proceed as follows:

Error messages

Meaning

Remedy

BLANK MD

Nothing is recorded.

Replace it with another disc.

CAN’T EDIT

A track cannot be edited.

Change the stop position of the track and

 

 

then try editing it.

CAN’T REC

Recording cannot be performed correctly

Re-record or replace the MiniDisc.

 

due to vibration or shock in the unit.

Replace it with another disc.

 

Timer recording is impossible or there is no

 

 

available space on the MD.

 

CD NO DISC

A CD has not been loaded.

Load a CD.

 

The disc data cannot be read.

Reload the CD.

DISC FULL

The disc is out of recording space.

Replace the disc with another recordable

 

 

disc.

FOCUS ERR

A disc has not been loaded.

Reload the MiniDisc.

 

The disc data cannot be read.

 

MD ERR

Trouble is found.

Contact the shop where you purchased the

 

 

unit.

MD NO DISC

A MiniDisc has not been loaded.

Load a MiniDisc.

 

The disc data cannot be read.

Reload the MiniDisc.

MECHA ERR*

There is a mechanical problem and the disc

Set this unit to the stand-by mode and press

(*:Number or

is not working properly.

the MD EJECT button.

symbol)

 

 

NAME FULL

The number of characters for the disc name

Shorten the disc or track name.

 

or track name exceeds 40.

 

NOT AUDIO

The data recorded on this disc is not audio

Select another track.

 

data.

Replace the disc.

PLAY MD

You tried to record on a playback-only disc.

Replace it with another recordable disc.

PROTECTED

The disc is write protected.

Move the write protection tab back to its

 

 

original position.

READ ERR

The disc is damaged.

Reload the disc or replace it.

 

A TOC is not written on the MD or there is

 

 

something wrong with data.

 

TEMP OVER

The temperature is too high.

Set this unit to the stand-by mode and wait

 

 

for a while.

TOC ERR*

The disc is damaged.

Replace it with another disc.

(*:Number or

TOC information cannot be read.

 

symbol)

MD not specified.

 

 

 

TOC FULL*

There is no space left for recording charac-

Replace it with another recordable disc.

(*:Number or

ter information (track names, disc names,

 

symbol)

etc.).

 

TOC W ERR

Recording is impossible.

Contact the shop where you purchased the

 

 

unit.

U TOC ERR*

TOC information recorded on the MD does

Replace it with another disc.

(*:Number or

not match the MD specifications or it can-

Erase the disc and try recording again.

symbol)

not be read.

 

U TOC ERR W

The TOC information could not be created

Set this unit to the stand-by mode and try to

 

properly due to a mechanical shock or to

write the TOC again. (Remove any source

 

scratches on the disc.

of shock or vibration whilst writing.)

? DISC

The data contains an error.

Replace it with another disc.

00:00

Music is not being recorded.

Replace the disc with another recordable

 

 

disc.

 

 

 

47

Page 48
Image 48
Sharp MD-M2H operation manual Error Messages, When an error message is displayed, proceed as follows

MD-M2H specifications

The Sharp MD-M2H is a versatile portable MiniDisc recorder that gained popularity for its compact design and advanced features, catering to music lovers and professionals alike. One of the standout features of the MD-M2H is its ability to record audio in high-quality formats, offering both stereo and mono options. This flexibility appeals to various users, including musicians, journalists, and audiophiles seeking pristine sound quality.

Equipped with a digital input, the MD-M2H allows users to connect directly to other digital devices, ensuring minimal loss of audio quality during transfers. The device also supports a unique ATRAC (Adaptive Transform Acoustic Coding) compression algorithm, which maintains the integrity of the original recording while significantly reducing file sizes. This technology enables longer recording times on a single MiniDisc, making it ideal for extended sessions.

Another important aspect of the MD-M2H is its user-friendly interface. The device features an intuitive control layout that facilitates easy navigation through its various functions. With an LCD display, users can easily monitor battery life, recording time, and other essential information at a glance. The inclusion of external microphone inputs adds to its adaptability, allowing for enhanced audio capture in diverse environments.

The Sharp MD-M2H is powered by rechargeable batteries, appealing to environmentally conscious users while providing the convenience of extended playback and recording times. Its compact and lightweight design, combined with a robust build, makes it perfect for on-the-go recording, whether that’s in the studio, at concerts, or while traveling.

In summary, the Sharp MD-M2H stands out for its high-quality audio recording capabilities, user-friendly design, and advanced compression technology. Its adaptability makes it a valuable tool for a wide range of applications. Whether for personal use or professional purposes, the MD-M2H continues to impress with its performance and reliability, cementing its place in the world of portable audio recording.