U.S.A. ONLY

Replacing the Projection Lamp

CAUTION

Potential hazard of glass particles if lamp ruptures. Please have Sharp Authorized Projector Dealer or Service Center replace lamp if rupture occurs.

Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely hot. Wait at least one hour after the power cord is disconnected to allow the surface of the lamp cage to fully cool before removing the lamp cage.

It is recommended that the lamp be replaced after approximately 1,400 cumulative hours of use or when you notice a significant deterioration of the picture and color quality. Carefully change the lamp by following the steps below.

If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorized Projector Dealer or Service Center for repair. Purchase a replacement lamp unit (lamp cage/module) of the current type BQC-PGM15X//1 from your nearest Sharp Authorized Projector Dealer or Service Center. Then carefully change the lamp by following the instructions below. If you wish, you may have the lamp replaced at your nearest Sharp Authorized Projector Dealer or Service Center.

IMPORTANT NOTE TO U.S. CUSTOMERS:

The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this projector under warranty, including lamp replacement, must be obtained through a Sharp Authorized Projector Dealer or Service Center. For the name of the nearest Sharp Authorized Projector Dealer or Service Center, please call toll- free: 1-888-GO-SHARP (1-888-467-4277).

Removing and installing the lamp unit

CAUTION

Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage or the inside of the projector.

To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.

1 Turn off the power.

2 cord.Disconnect the power

3 cover.Remove the lamp cage

Press ON/OFF on the projector

Unplug the power cord from the

Turn over the projector and

or POWER on the remote

AC socket.

loosen the user service screws

control. Wait until the cooling

 

that secure the lamp cage cover.

fan stops.

 

Then lift open the cover in the

 

 

direction of the arrow.

or

 

 

4 cage.Remove the lamp

5 Insert the new lamp cage.

6 cover.Attach the lamp cage

Loosen the securing screws on

Press the lamp cage firmly into

Slide the lamp cage cover in the

the lamp cage. Hold the lamp

the lamp cage compartment.

direction of the arrow. Then

cage by the handle and pull it

Fasten the securing screws.

tighten the user service screws.

towards you.

 

 

Troubleshooting

Maintenance&

 

 

 

 

 

 

 

 

47

Page 49
Image 49
Sharp PG-M15X appendix Replacing the Projection Lamp, Removing and installing the lamp unit, Cord.Disconnect the power