Controlling the Monitor with a PC (RS-232C)
Others
Function | Command | Direction | Parameter | Reply | Control/Response contents | *1 | *2 | |||
|
| |||||||||
(A) | (B) | |||||||||
|
|
|
|
|
|
|
|
|
|
|
SCREEN SIZE (PC) |
| WIDE | WR | 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2 | ○ |
|
| |||
SCREEN SIZE (AV) |
| WIDE | WR | 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot | ○ |
|
| |||
VOLUME |
| VOLM | WR |
| ○ |
|
| |||
MUTE |
| MUTE | WR | 0: OFF, 1: ON | - |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
INFORMATION |
| MODEL | INF1 | R |
| Value |
| ● |
|
|
|
|
|
|
|
|
|
|
|
| |
|
| SERIAL NO | SRNO | R |
| Value |
|
|
| |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
BRIGHT |
| VLMP | WR |
| ○ |
|
| |||
TEMPERATURE SENSOR | DSTA | R |
| 0 | Internal temperature normal |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | Internal temperature abnormal (Standby mode) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | Internal temperature abnormal (Temperature is normal now, but it was | ● |
|
|
|
|
|
|
|
|
| abnormal during operation.) |
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 3 | Internal temperature abnormal (Brightness of the backlight decreases.) |
|
|
|
|
|
|
|
|
| 4 | Temperature sensor abnormal |
| ○ | ○ |
Temperature acquisition | ERRT | R |
| Value | Temperature at temperature sensors 1 through 3 are returned in the |
| ||||
|
|
|
| |||||||
|
|
|
|
|
|
| following forms: | ○ |
|
|
|
|
|
|
|
|
| [Sensor 1], [Sensor 2], [Sensor 3] |
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Indicates a temperature sensor abnormality when “126” is returned. |
|
|
|
CAUSE OF LAST STANDBY MODE | STCA | W | 0 |
| Initialization |
|
|
| ||
|
|
|
| R |
| 0 | No detectable error has occurred |
|
|
|
|
|
|
|
|
| 1 | Standby mode by POWER button |
|
|
|
|
|
|
|
|
| 2 | Main power off by the main power switch | ● |
|
|
|
|
|
|
|
| 3 | Standby mode by |
|
| |
|
|
|
|
|
| 4 | Input signal waiting mode by No Signal |
|
|
|
|
|
|
|
|
| 6 | Standby mode by abnormal temperature |
|
|
|
|
|
|
|
|
| 8 | Standby mode by SCHEDULE setting |
|
|
|
|
|
|
|
|
| 20 | Standby mode by OFF IF NO OPERATION setting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Commands for setting of the GAMMA user data
Function | Command | Direction | Parameter | Reply | Control/Response contents | *1 | *2 | |
(A) | (B) | |||||||
|
|
|
|
|
|
|
|
|
RED GAMMA DATA TRANSFER | UGRW | W | aaxxxx ··· xxxxcc |
| aa: Block number |
|
|
|
GREEN GAMMA DATA TRANSFER | UGGW | W | (xxxx: 32 pieces) |
| xxxx: 32 pieces of user data |
|
|
|
|
|
| aa: |
| cc: Checksum (ASCII data) of the block number and user data |
|
|
|
BLUE GAMMA DATA TRANSFER | UGBW | W |
|
|
|
| ||
xxxx: |
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
|
|
| cc: |
|
| ○ | ○ | ○ |
|
|
|
|
|
| |||
RED GAMMA DATA READ | UGRR | W | xxxx ··· xxxx | xxxx: User data of 32 pieces | ||||
GREEN GAMMA DATA READ | UGGR | W | (xxxx: 32 pieces) |
|
|
|
| |
|
|
|
| xxxx: |
|
|
|
|
BLUE GAMMA DATA READ | UGBR | W |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
USER DATA INITIALIZE | UGRS | W | 0 |
| Initialize the user data. |
|
|
|
|
|
|
|
|
|
|
|
|
USER DATA SAVE | UGSV | W | 0 |