Sharp PN-E602 Controlling the Monitor with a PC RS-232C, PC connection, Communication conditions

Models: PN-E602

1 57
Download 57 pages 56.78 Kb
Page 30
Image 30
Controlling the Monitor with a PC (RS-232C)

Controlling the Monitor with a PC (RS-232C)

You can control this monitor from a PC via RS-232C (COM port) on the PC.

You can also connect multiple monitors via a daisy chain by using a PC. By assigning ID numbers to each monitor (see page 31), you can make input mode selection/adjustment or can check the status of a specific monitor.

Precautions when the PN-ZB01 (optional) is attached

To control the monitor via RS-232C, set RS-232C/LAN SELECT to RS-232C.

You cannot use RS-232C and LAN control simultaneously.

PC connection

nOne-to-one connection with a PC

Connect with RS-232 straight cable between the PC’s COM port (RS-232C connector) and the RS-232C input terminal on the monitor.

Precautions when the PN-ZB01 (optional) is attached RS-232C input terminal

PC

To COM port

RS-232 straight cable (commercially available)

nDaisy chain connection… Advanced operation

Connect with RS-232 straight cable between the PC’s COM port (RS-232C connector) and the RS-232C input terminal on the first monitor.

Next, connect RS-232 straight cable to the first monitor’s RS‑232C output terminal and to the second monitor’s RS-232C input terminal. Connect in the same way to the third and subsequent monitors.

Up to 25 monitors can be connected. (Depending on the length of the cable used and the surrounding environment.)

First monitor

Second monitor

Communication conditions

Set the RS-232C communication settings on the PC to match the monitor’s communication settings as follows:

Baud rate

*

 

Stop bit

1 bit

 

 

 

 

 

Data length

8 bits

 

Flow control

None

 

 

 

 

 

Parity bit

None

 

 

 

 

 

 

 

 

*Set to the same baud rate as the BAUD RATE setting of SETUP menu. (Initial setting: 38400 bps)

*When connecting multiple monitors in a daisy chain, set all monitors to the same BAUD RATE.

Communication procedure

nCommand format

When a command is sent from the PC to the monitor, the monitor operates according to the received command and sends a response message to the PC.

 

 

 

 

 

 

 

 

 

 

Return code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

 

C2

C3

 

C4

 

P1

P2

P3

P4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command field

 

 

 

Parameter field

 

 

(4 prescribed

 

 

(4 character string comprised of:

alphanumerical characters)

 

0-9, +, -, space, ?)

Example: VOLM0030

VOLM 30

*Be sure to input 4 characters for the parameter. Pad with spaces (“ ”) if necessary.

(“ PC connectionnOne-to-one connection with a PCnDaisy chain connection… Advanced operationCommunication conditions ” is a return code (0DH, 0AH or 0DH))

Wrong : VOLM30Communication procedurenCommand formatManual backgroundManual background

Right : VOLM

30

When inputting a negative value, specify a numerical value in three digits.

Example: AUTR-005

Do not use spaces for MPOS, DATE, and SC01 through SC08. Specify parameters using a specified number of characters.

Example: MPOS010097

RS-232C output terminal

RS-232C Manual background input terminal Manual background

PC

 

To COM port

RS-232 straight cables

(commercially available)

If a command has “R” listed for “DIRECTION” in the “RS-232C command table” on page 34, the current value can be returned by using “?” as the parameter.

Example:

VOLM ? ? ? ?

From PC to monitor (How much

 

 

is current volume setting?).

30

From monitor to PC (Current

 

 

volume setting: 30).

*If an ID number (see page 31) has been assigned

(For example, ID number = 1).

VOLM

?

From PC to monitor.

30 001

From monitor to PC.

E30

Page 30
Image 30
Sharp PN-E602 Controlling the Monitor with a PC RS-232C, PC connection, Communication conditions, Communication procedure