Sharp PN-E602 Controlling with a PC, Basic operation, Controlling the Monitor with a PC LAN

Models: PN-E602

1 57
Download 57 pages 56.78 Kb
Page 44
Image 44
Controlling with a PC

Controlling the Monitor with a PC (LAN)

6. Click on “LAN SETUP” under NETWORK.

7. Specify the “DHCP CLIENT”, “IP ADDRESS”,etc.

Controlling with a PC

■ Basic operation

You use Internet Explorer on a PC on the LAN to control the monitor.

1.Launch Internet Explorer on the PC.

2.In the “Address” box, type “http://” followed by your monitor’s

IP address followed by “/”, then press the Enter key.

You can confirm the IP address with the DISPLAY function.

When prompted to enter a user name and password, type the user name and password that you specified in the security settings (see page 46), and click [OK].

If you did not make any security settings, leave the spaces blank and click on [OK].

3.You can check, control, and change the monitor’s status and settings by clicking the menu items on the left side of the screen.

DHCP CLIENT

If your LAN has a DHCP server and you wish to obtain an address automatically, change this setting to “ON”.

To set the address manually, set this to “OFF”.

IP ADDRESS

If the DHCP CLIENT is set to “OFF”, specify an IP address.

SUBNET MASK

If the DHCP CLIENT is set to “OFF”, specify the subnet mask.

DEFAULT GATEWAY

If the DHCP CLIENT is set to “OFF”, specify the default gateway. If you are not using a default gateway, specify “0.0.0.0”.

8.When the setting is changed, click [Apply].

9.Check the message and click [OK].

10.Exit Internet Explorer.

11.Restore the PC’s IP address jotted in Step 6, “(2) Specifying the PC’s IP address”.

12.Connect the monitor and the PC to the LAN.

■ Basic operation Caution

Wait 10 seconds after clicking [OK] before proceeding.

When operating using the remote control unit or similar, click [Refresh].

TIPS

When the IP address is set manually, the IP addresses of the monitor connected to the RS-232C output terminal and the daisy chain of connected monitors that follows can be assigned automatically. (See page 23.)

If you see an [Apply] button next to a setting, click it after you change that setting.

TIPS

See pages 45 to 49 for details on each setting.

If you click [Refresh] before the screen finishes updating the current display, the “Server Busy Error” will appear. Wait for a moment before operating your monitor again.

You cannot operate the monitor while it is warming up.

If “DHCP CLIENT” is set to “ON”, press DISPLAY on the remote control unit two times and then check the monitor’s IP address.

E44