Sharp operation manual 180 mm, 20 mm, Hole, A30317, SUK R-21AT O/M, Building-In-Kit

Models: R-21AT

1 36
Download 36 pages 17.28 Kb
Page 7
Image 7
BUILDING-IN-KIT

A30317, SUK R-21AT O/M

8.The unit may be secured to a countertop or stand. There is a screw hole in the bottom of the unit. After the oven is permanently placed, drill a hole through the counter top for a 5 mm self-tapping screw. The hole should be 20 mm from the left side of the outer case cabinet and 180 mm back from the front edge of the cavity face plate.

!WARNING:

It is hazardous for anyone other than a Service Tech- nician, approved by SHARP to carry out any service or repair operation which involves the removal of a cover which gives protection against exposure to mi- crowave energy.

BUILDING-IN-KIT

This oven is not designed to be built into a kitchen unit.

IMPORTANT! ELECTRICAL CONNECTION

Do not allow water to come into contact with the power supply cord or plug.

Insert the plug properly into the socket as the plug may otherwise overheat and catch fire.

Do not connect other appliances to the same socket using an adaptor plug as it may cause the house wiring to overheat and catch fire.

If the plug or socket is loose or the power supply cord is damaged, do not operate the oven, it must be replaced by the special power cord, part no. QACC-A088WRE0. Contact your dealer or a Service Technician appointed by SHARP.

A defective plug, power supply cord or socket may overheat and catch fire during operation or cause an electrical shock.

180 mm

20 mm

Hole

 

When removing the plug from the socket always grip the plug, never the mains lead as this may damage the power supply cord and the connections inside the plug.

The product is fitted with a non-rewireable (moulded) plug. Should it not be suitable for the socket outlet in your kitchen, remove the plug and fit an appropriate type, observing the wiring code given in "To replace the mains plug" on page 33.

The fuse from a cut-off plug should be removed and the plug disposed of in safe manner. Under no circumstances should the cut-off plug be inserted into a socket outlet as serious electrical shock may occur. The plug must not be used without the fuse cover fitted.

When replacing the plug please ensure that you use a BSI or ASTA approved plug to BS1363, this should be fitted with a brown coloured 13 amp fuse approved by BSI or ASTA to BS1362. If you have any doubt about electrical connection seek the help of a qualified electrician.

!WARNING

THIS APPLIANCE MUST BE EARTHED.

To wire an appropriate plug, follow the wiring code given in "To replace the mains plug" on page 33.