SERVICE CALL CHECK
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely. Operate the oven for one minute at HIGH 100%.
A. Does the oven light come on? | YES _______ NO _______ |
B. Does the cooling fan work? | YES _______ NO _______ |
(Put your hand over the rear ventilating openings.) |
|
C. Does the turntable rotate? | YES _______ NO _______ |
It is normal for the turntable to turn in either direction. |
|
D. Is the water in the oven warm? | YES _______ NO _______ |
If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker. If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER.
A microwave oven should never be serviced by a
NOTE: If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 13 and cancel.
SPECIFICATIONS
|
|
|
AC Line Voltage: | Single phase 120V, 60Hz, AC only | Single phase 120V, 60Hz, AC only |
AC Power Required: | 1500W 13.0 amps. | 1370W 12.0 amps. |
Output Power: |
|
|
Microwave | 1000W (IEC Test Procedure) | 900W (IEC Test Procedure) |
Frequency: | 2450 MHz | 2450 MHz |
Outside Dimensions: | 201/2”(W) x 117/8”(H) x 157/8”(D) | 201/2”(W) x 117/8”(H) x 157/8”(D) |
Cavity Dimensions : | 133/4”(W) x 83/8”(H) x 147/8”(D) | 133/4”(W) x 83/8”(H) x 147/8”(D) |
Oven Capacity : | 1.0 Cu.Ft. | 1.0 Cu.Ft. |
Cooking Uniformity: | Turntable system, 131/4” diameter | Turntable system, 131/4” diameter |
Weight: | Approx. 33 lbs. | Approx. 33 lbs. |
The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method is widely recognized.
Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.
FCC | – Federal Communications Commission Authorized. | |
DHHS | – | Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter |
|
| I, Subchapter J. |
| – | This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. |
®
15