Sharp SND-5080 user manual Exposure Setup, Brightness

Models: SND-5080

1 101
Download 101 pages 20.07 Kb
Page 57
Image 57

Exposure Setup

You can adjust the exposure level of the camera.

▲/▼ Ö ENTER Ö ▲/▼/◄/► Ö ENTER Ö ▲/▼/◄/► Ö ENTER

1.Move to <EXPOSURE> and select a setting value.

MAIN SETUP

 

SSDR

ON

WHITE BAL

ATW

BACKLIGHT

OFF

EXPOSURE

 

SPECIAL

 

EXIT

 

M CAMERA SETUP

2.Select each item and set it appropriately. y BRIGHTNESS : Adjust the screen

brightness.

y IRIS : If set to <MANUAL>, you can adjust the iris of the camera manually.

y SHUTTER : Adjust the electronic shutter of the camera.

-MANUAL : Adjust the shutter speed of the camera manually.

EXPOSURE SETUP

BRIGHTNESS

‚‚‚‚‚‚‚‚‚‚‚‚ ‚‚‚‚‚‚‚‚‚‚‚‚ 50

IRIS

AUTO

SHUTTER

---

AGC

HIGH

SSNR3

ON

SENS-UP

AUTO

RETURN

 

- A.FLK : This will prevent the screen from flickering.

yAGC : Specify how to adjust the level according to the luminance.

- MANUAL : Adjust the screen brightness manually.

ySSNR3 : Adjust the noise reduction level.

SSNR3 LEVEL SETUP

LEVEL

‚‚‚‚‚‚‚‚‚ ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 12

RETURN

 

English _57

Page 57
Image 57
Sharp SND-5080 user manual Exposure Setup, Brightness