setup screen

To use the IV analysis function according to the whole area based rule

1.Set <IV analysis function> to <Enable>.

2.Set the event rule to <Entire area based rules>.

3.Select a desired <Entire Area Rules>. y Appearing : An event where an object

that has not existed suddenly appears will be detected.

y Disappearing : An event where an object that has existed suddenly disappears will be detected.

y Scene Change : An event where the screen is changed at more than a certain time interval will be detected.

You can set the <Scene Change> rule along with rules : <Appearing> and <Disappearing>.

4.Click [OK].

5.When done, click [Apply].

Time Schedule

You can configure so that an event will occur at a scheduled time regardless of the actual occurrence of the event.

1.From the Setup menu, select the

<Event ( )> tab.

2.Click <Time Schedule>.

To set the timer event

1.Set <Timer Event Setup> to Enable.

2.Specify the <Activation time>.

y Always : Always sends an image at the set interval.

y Only scheduled time : Periodically transfers image only at a specified time and date.

3.Specify the <Transfer interval>.

82_ setup screen