Enter the PGM2 mode from the mode selection window.
Enter the PGM2 mode from the mode selection window.

5.Specifying whether to enable or disable the system retry function when a transmission error occurs – master and satellite

You can specify whether to enable or disable the system retry function if a communication between machines does not end successfully.

This function can be specified in the INLINE CONFIG window of the master and each satellite in the IRC system.

1.

2. Select “2 SETTING” from the displayed menu. The SETTING window will appear.

3. Select “21 INLINE CONFIG” from the displayed menu. The INLINE CONFIG window will appear.

4. Touch the “SYSTEM RETRY” line and select “ENABLE” or “DISABLE”, and then touch the [CONTINUE] key to complete the setting. (The following is applied only in the case of the setting at the master.)

The MASTER LIST window will appear.

5. Touch the [CONTINUE] key again to close the MASTER LIST window.

NOTE

• If the system retry function is enabled, a transmission job with which an error has occurred is

not finalized immediately, but the master waits for selection of one of the three commands

 

 

(RETRY, ABORT and IGNORE). Then the master retries access to the satellite that has

 

caused the transmission error or terminates the access as a successful or unsuccessful

 

transmission depending on the selection made.

If the function is disabled, the job is terminated immediately.

For further information, see the “System retry function” section on pages 55–56.

The default setting is “ENABLE.”

6.Choosing whether to search the master or satellite first for the PLU/EAN code – satellite

At a satellite, you can choose which machine, either the master or the satellite, should be searched first for the PLU/EAN code. If you specify that the master should be searched first and enter the PLU/EAN code, the master is first searched and then the satellite is searched, and vice versa.

However, either choice of search order made at the master is invalid. In other words, even if you specify at the master that the satellite should be first searched, the master will be first searched.

1.

2. Select “2 SETTING” from the displayed menu. The SETTING window will appear.

3. Select “21 INLINE CONFIG” from the displayed menu. The INLINE CONFIG window will appear.

4. Touch the “LOOKUP ORDER” line and select “MA” or “SA”, and then touch the [CONTINUE] key.