Sharp UP-600, UP-700 instruction manual Flow of a recovery declaration at the master

Models: UP-700 UP-600

1 61
Download 61 pages 55.57 Kb
Page 54
Image 54
Flow of a recovery declaration at the master

(2)When the back-up master recovers from a breakdown — Recovery declaration at the master

1)The recovery declaration operation is done at the master.

2)Each satellite stops sending updated GLU/PBLU data to the master temporarily.

3)The master sends the updated GLU/PBLU data files to the back-up master.

4)The master informs all satellites of the back-up master’s recovery.

5)The satellites restart sending updated GLU/PBLU data to the back-up master and master.

Flow of a recovery declaration at the master

Master

Back-up master

3) Updated data file

1) Recovery declaration Manual background (Processing)

Satellite

4)Back-up master recovery information

2)Transmission stops temporarily.

5) Restart of updated data transmission

The recovery declaration procedure is the same as “(1) When the master recovers from a

breakdown.”