Sharp UP-700, UP-600 instruction manual Clearing procedure

Models: UP-700 UP-600

1 61
Download 61 pages 55.57 Kb
Page 57
Image 57
Manual background

(6) Data clearing of the server sign-on state — master

You can clear the master’s server sign-on status flags in case of trouble.

This operation is effective only for the sign-on flag for servers who have remained signed on at the master.

Clearing procedure

After selecting “DATA CLEAR” from the PGM2 mode menu with the same procedure as steps 1 and 2 in “(1) Data clearing of the T-LOG buffer,” select “SIGN ON FLAG.”

NOTE

The server sales data for each server who has signed on is not collected when the manual clearing of the sign-on state is performed. Server sales data is collected only when the sign-off operation is done correctly at the satellites.

(7) Data clearing of the GLU/PBLU data in use — master

You can clear the GLU/PBLU data in use at the master in the event some trouble has occurred.

This operation clears all GLU/PBLU data that is currently in use.

Clearing procedure

After selecting “DATA CLEAR” from the PGM2 mode menu with the same procedure as steps 1 and 2 in “(1) Data clearing of the T-LOG buffer,” select “GLU USED FLAG.

56

Page 57
Image 57
Sharp UP-700, UP-600 instruction manual Clearing procedure