•Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws.
•Align the lamp unit cover and slide it to close. Then tighten the user service screw to secure the lamp unit cover.
Info
•If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.Info |
| |
• Make sure to reset the lamp timer only | AC socket | |
when replacing the lamp. If you reset the | ||
| ||
lamp timer and continue to use the same |
| |
lamp, this may cause the lamp to become |
| |
damaged or explode. |
|
•You can also reset the lamp timer via the
LAN.
(Refer to the SETUP MANUAL on the supplied
• Plug the power cord into the AC socket of the projector.
2 Reset the lamp timer.• While simultaneously holding down ",
ENTER and MENU on the projector, press STANDBY/ON on the projector.
•“LAMP 0000H” is displayed, indicating that the lamp timer is reset.
STANDBY/ON button
ENTER button"button MENU button