Regarding the Lamp (Continued)

Regarding the Lamp (Continued)

4 Remove the lamp unit.

Loosen the securing screw from the lamp unit. Hold the lamp unit and pull it in the

direction of the arrow. At this time, keep

Securing

screw

the lamp unit horizontal and do not tilt it.

54 Remove the lamp unit.Insert the new lamp unit.

6Replace the lamp unit cover.Resetting the Lamp Timer

Insert the new lamp unit.

Press the lamp unit fi rmly into the lamp unit compartment. Fasten the securing screw.

Replace the lamp unit cover.

Align the tab on the lamp unit cover

(1) and close it (2). Then tighten the user service screw (3) to secure the lamp unit cover.

1Connect the power cord and open the lens shutter fully. Info

If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.

2 Reset the lamp timer. Info

Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode.

1Connect the power cord and open the lens shutter fully.

Plug the power cord into the AC socket of Manual background the projector.

2Manual backgroundManual background Reset the lamp timer.

While simultaneously holding down MENU, ENTER and R on the projector, press STANDBY/ON on the projector and keep all four buttons pressed down until the lamp indicator starts blinking green.

“LAMP 0000H” is displayed, indicating that the lamp timer is reset.

AC socket

STANDBY/ON button

ENTER button

Manual backgroundManual backgroundManual background MENU button R button

58

Page 62
Image 62
Sharp XR-55X Regarding the Lamp Continued, Resetting the Lamp Timer, Remove the lamp unit, Insert the new lamp unit, Info