6Insert the new lamp unit.
Press the lamp unit firmly into the lamp
unit compartment. Fasten the secur-
ing screws.
7Attach the lamp unit cover.
Slide the lamp unit cover in the direc-
tion of the arrow.
Fasten the user service screw.

Resetting the Lamp

Timer

Reset the lamp timer after replacing the lamp.
1Plug the power cord.
Confirm that the POWER indicator il-
luminates red.
2Reset the lamp timer.
Press , , , , and
in order. Then press .
LAMP 0000H is displayed on the
screen.
Info
Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, the lamp may become damaged or
explode.
ON buttonUNDO button
INPUT button
ENTER button
Power cord
XV_Z200E_E_p57_66.p65 03.10.30, 13:15PM61