Image 10
Install blade stiffener

ENGLISH

Install blade stiffener

1.Move stop switch to stop position.

2.Disconnect spark plug wire.

WARNING

Hedge trimmer blades are very sharp. Touching them may lead to severe personal injury. Use a socket and extension when adjust- ing blade bolts or blade locknuts in order to keep hands at a safe distance from sharp blades.

3.Lay unit on muffler side and hold securely in place.

4.Remove first four blade locknuts (A) and washers in front of front handle/guard. Do not remove blade bolts.

5.Tighten blade bolts (B) until snug. Install blade stiffener, then washers.

6.Loosen blade bolts ½ turn. Secure blade stiffener with new locknuts

(A). Hold blade bolts from turning using a 10mm wrench.

Note

Use new locknuts every time blade stiffener is installed.

IMPORTANT

If blade stiffener is damaged or show signs of wear, replace it.

Note

Washers (C) should be movable by hand after blade bolts are adjusted properly.

A Blade stiffener removal

B

C

Blade stiffener removal

1.Move stop switch to stop position.

2.Disconnect spark plug wire.

Manual background WARNING

Hedge trimmer blades are very sharp. Touching them may lead to severe personal injury. Use a socket and extension when adjust- ing blade bolts or blade locknuts in order to keep hands at a safe distance from sharp blades.

3.Remove blade stiffener locknuts (A) and washers. Do not remove blade bolts.

4.Remove blade stiffener.

5.Tighten blade bolts (B) until snug, then loosen ½ turn.

6.Secure blades with new locknuts (A). Hold blade bolts from turning using a 10mm wrench.

A Manual background

B

10

Page 10