Shindaiwa EB8520RT EVC, 68915-94310 manual Assembling the RT Blower

Models: 68915-94310 EB8520 EB8520RT EVC

1 60
Download 60 pages 22.78 Kb
Page 7
Image 7

Assembly (continued)

Assembling the RT Blower

IMPORTANT!

This unit is equipped with a static dis- charge reduction wire. This wire helps direct static buildup into the air stream reducing the felt amount to the operator.

1.

Place the blower upright on the ground

 

or a sturdy work surface and note parts

 

orientation as shown in Figure 7.

2.

Remove static wire from package and

 

fix eyelet to right hand engine cover

 

screw. See Figure 8.

3.

Turn the discharge tube out to a right

 

angle and slip anti-static wire through

 

the 102mm clamp and flexible tube.

4.

Install throttle cable holder just forward

 

of the 102 mm clamp, pinching loops

 

together to fit over end of flexible tube.

 

 

 

 

 

Throttle

 

 

 

 

Swivel

Assembly

 

 

 

 

 

 

 

 

 

Tube

 

 

 

 

Flexible Tube

 

Long Nozzle (ø74 mm)

 

 

 

 

 

 

 

Throttle Cable

 

 

 

 

Holder

 

 

 

 

 

90° Discharge

 

Straight Tube

 

 

 

 

 

 

 

Tube

 

 

 

 

Anti-Static

102mm

 

 

 

Figure 7

Wire

89mm Clamp

Swivel Tube

Short Nozzle

 

Clamp

(ø65 mm)

 

 

 

 

 

 

See Figures 10A and 10B.

5.

Slip the flexible tube over the end of the

 

90° discharge tube, and secure with the

 

102 mm clamp.

6.

Slide the throttle assembly over the swivel

 

tube. Do not tighten clamp at this time.

NOTE:

Check to make sure that the 90° dis- charge tube swivels freely. If any binding is present, loosen 102 mm clamp and pull wire towards engine to get more slack and recheck for free movement.

7.Insert the static wire through the swivel tube, then install and tighten the 89mm clamp over the rotating band on the swivel tube.

8.Fold the end of the static wire back over the connection of the swivel tube. See Figure 8.

9.Grasp the nozzle, and push the nozzle over the swivel tube locking pins secur- ing the static wire. See Figure 9.

10.Lock the nozzle to the swivel tube by rotating the nozzle noting the alignment marks. See Figure 9.

11.Adjust throttle assembly for best operator comfort and tighten two socket-head screws.

Throttle

 

Assembly

 

 

Fold Wire

Swivel

 

Tube

 

Throttle Cable

Flexible Tube

Holder

 

Static Wire

Static Wire

 

Connector

 

Figure 8

 

Loops

 

Figure 10A

Throttle Cable Holder

Figure 10B

Align the lock pins with the lock slots, and push the tube and nozzle together.

A

Lock Pin

Lock Slot

Rotate clockwise to lock making sure the 3 lines are aligned on both tube and nozzle.

B

Figure 9

IMPORTANT!

Blower tube installation affects blower performance! Make sure the tubes and nozzle are correctly assembled per above, and that all connections are tight. Blower tubes may come apart during use unless tubes are aligned and locked into place.

WARNING!

Danger from rotating impeller!

Stop the engine before installing or removing the blower tubes! Never perform any maintenance or assem- bly procedures on this unit while the engine is running!

The blower should now be ready

for use.

7

Page 7
Image 7
Shindaiwa EB8520RT EVC, 68915-94310 manual Assembling the RT Blower