Assembly (continued)

Assembly (continued)

Cutting Attachment Shield - T, TX unit

1.Insert the cutting attachment shield between the outer tube and the cutting attachment mounting plate.

NOTE:

It may be necessary to loosen the retain- ing nut and clamp screw to adjust cutting attachment shield mounting plate.

2.Fit the two shims and the bracket over the outer tube and loosely install the four socket-head screws.

3.Tighten the four socket-head cap screws to secure the cutting attach- ment shield.

CAUTION!

Make sure the clamp screw and retaining nut are securely tightened before tightening the four socket- head cap screws.

WARNING!

NEVER operate the unit with- out the cutting attachment shield installed and tightly secured!

Sub-Shield

(when trimmer head is in use)

1.Attach the shield extension to the cutting attachment shield.

WARNING!

NEVER use this machine with- out sub-shield when using a trimmer head.

CAUTION!

Make sure the sub-shield is completely hooked at the hook receiver.

 

 

T unit

Socket-

 

 

Head Cap

 

Outer Tube

Screws

Bracket

 

Shim

 

Cutting Attachment

 

Shield

 

 

Clamp Screw

 

 

 

Shim

Line Cutter

Mounting

Plate

 

Retaining

 

 

Nut

 

 

TX unit

Socket-Head

Bracket

Outer Tube

Cap Screws

 

 

Shim

Clamp Screw

Shim

Mounting Plate

Retaining

NutCutting Attachment

Shield w/subshield

Cutting Attachment Shield - T, TX unitLine Cutter

Cutting Attachment Shield

Hook Receiver

Sub-shieldHook

Attach the sub-shield to the cutting attachment shield for TX units when using a trimmer head