This catalog is out of date, see note on page 3

Process I/Os

ET 200S

ET 200S

Overview

The ET 200S is a bit-modular distributed I/O system with degree of protection IP 20. The bit modularity of the ET 200S permits op- timum, rapid adaptation to the respective automation task. The setting-up times can be minimized even with frequently chang- ing demands by replacing or combining various I/O modules. The range of I/Os includes analog and digital signal modules, process modules and consumer feeders (modules for switching and protecting three-phase consumers up to 5.5 kW).

The ET 200S has a design with independent wiring, i.e. the wir- ing is carried out using terminal modules which function as a supporting system for power modules, electronics modules and consumer feeders. The terminal modules are latched onto a rail according to EN 50 022 and can be prewired and tested without I/O modules. This design also supports hot swapping of

I/O modules.

Design

The following components are available for the ET 200S distrib- uted I/O system:

Interface module to connect the ET 200S to the PROFIBUS-DP (IM 151 or IM 151 FO), or alternatively

IM 151/CPU or IM 151/CPU FO with additional integrated CPU 314 for preprocessing of process data

Terminal modules for DIN rail mounting including terminals (keyed connection system permits increased vibration resis- tance of 5 g); rail system for power modules, electronics mod- ules and consumer feeders

Power modules for electronics modules and consumer feed- ers;

for monitoring and fusing the load and sensor power supplies, and for monitoring the auxiliary voltages for a group of consum- er feeders

Electronics modules: analog and digital I/O modules, as well as special process modules (e.g. for recording SSI sensor val- ues, or for universal counter functions)

Consumer feeders (modules for switching and protecting any three-phase consumers up to 5.5 kW)

-Direct starters

-Reversing starters

Configuration limits when used on AS 488

Up to 32 modules can be inserted per I/O system.

The maximum address range of all inserted I/O modules is

122 byte for input data and 122 byte for output data. This limit is irrelevant to the CPU version.

The maximum number of parameters is limited to 244 byte per station. Process modules such as the counter module have long parameter sets, permitting the parameter limit to be reached pri- or to the limiting length of the process data.

Configuration

Configuration and parameterization

The ET 200S distributed I/O systems are configured and param- eterized using COM PROFIBUS.

Siemens PLT 112 · 2002

8/13

Page 74
Image 74
Siemens AS 488/TM manual ET 200S, Configuration limits when used on AS, Configuration and parameterization

AS 488/TM specifications

The Siemens AS 488/TM is a cutting-edge solution in the realm of industrial automation and control. Designed specifically for high-performance applications, this device serves as a programmable logic controller (PLC) offering enhanced capabilities for process automation. The AS 488/TM stands out in the marketplace for its robust architecture, sophisticated features, and compatibility with various industrial protocols.

One of the pivotal features of the Siemens AS 488/TM is its integrated communication capabilities. It supports multiple communication protocols, such as Profibus, Profinet, and Ethernet/IP, facilitating seamless integration within diverse industrial environments. This flexibility ensures that the AS 488/TM can communicate with various devices, sensors, and actuators, providing a comprehensive solution for modern manufacturing needs.

In terms of processing power, the AS 488/TM is equipped with a high-performance CPU that can handle complex algorithms and data processing with ease. This enables the controller to manage intricate automation tasks, from simple control functions to complex multi-axis motion control. The device also comes with expandable I/O options, allowing users to tailor the system to meet specific application requirements. With a wide range of digital and analog inputs and outputs, the AS 488/TM ensures accurate monitoring and control of various processes.

Another notable characteristic of the AS 488/TM is its user-friendly programming interface. Siemens has developed the TIA Portal (Totally Integrated Automation Portal), a software platform that simplifies the programming and configuration of the PLC. This intuitive interface allows users to program the device using various programming languages, including Ladder Logic, Function Block Diagram, and Structured Text. The TIA Portal enhances productivity by providing simulation tools for testing and debugging applications before deployment.

The AS 488/TM also emphasizes safety and reliability. It complies with international safety standards and incorporates features that ensure safe operation in critical applications. Redundant power supplies and fail-safe mechanisms are integrated to minimize downtime and protect both personnel and equipment.

Moreover, the Siemens AS 488/TM is designed with future scalability in mind. As industries evolve and technology advances, the AS 488/TM can adapt to new requirements, ensuring a long service life and ongoing relevance in a rapidly changing landscape. Overall, the Siemens AS 488/TM is an impressive PLC that combines innovative features, robust technology, and flexible integration capabilities, making it an ideal choice for modern industrial automation systems.