This catalog is out of date, see note on page 3

Process I/Os

SIWAREX M

SIWAREX M

Overview

In a process engineering application, SIWAREX M handles exe- cution of all weighing functions as well as the time-critical control of the dosing units (valves etc.) of dosing scales, independent of the time cycle of the automation system. Exact switching-off of the dosing valves is achieved in this manner, and thus an opti- mum of dosing accuracy.

SIWAREX M can be used to design net weight scales, single- component or multi-component scales, as well as multi-scale systems.

The downloadable SIWA driver block integrates the SIWAREX M weighing and dosing electronics with verification capability into the TELEPERM M process control system.

The SIWAREX M function modules are operated in ET 200M dis- tributed I/O systems. It is irrelevant whether the ET 200M is con- nected to the automation system via line 1 or 2 of the PROFIBUS- DP. Up to seven SIWAREX M function modules can be plugged into an ET 200M of standard design with bus connectors. Up to four SIWAREX M function modules can be plugged into an

ET 200M with active bus modules (for the hot swapping func- tion).

Configuration SIWA driver block

The AS 388/TM and AS 488/TM automation systems additionally require the SIWA driver block for connection of SIWAREX M. SIWA is a standard AS function block with the system type num- ber 138, and can be downloaded into the automation system via a commissioning terminal.

Users can call the following functions using so-called jobs:

"Measure"

"Tare"

"Start"

"Pause" (stopping of a dosing procedure)

"Continue" (continuation of a dosing procedure)

Status scanning is additionally possible for diagnostics.

The listed jobs can be activated using operator-accessible ele- ments and via configurable inputs. Following termination of a job by SIWAREX M, the driver block assumes the "Measure" status. Just like other operator-accessible blocks, SIWA also offers a status word which can be acknowledged by an operator system.

Note:

The SIWA driver block can only execute on the automation sys- tem whose serial number is stored in the SIWA software. If the SIWA driver block is subsequently ordered, it is therefore neces- sary to specify the memory card serial number of the automation system on which the SIWA is to be installed.

Ordering Data

 

Order No.

SIWAREX M function module

7MH4 553-1AA41

Weighing and dosing system

 

SIWA driver block

6DS5 470-1AD

for AS 388/TM and AS 488/TM

 

automation systems

 

 

 

Connection of SIWAREX M modules, configuration example

ET 200M with SIWAREX M function modules can be operated on lines

1and 2 of the PROFIBUS-DP. Only one PROFIBUS-DP line is shown in this configuration example.

8/16

Siemens PLT 112 · 2002

Page 77
Image 77
Siemens AS 488/TM manual Siwarex M, Configuration Siwa driver block

AS 488/TM specifications

The Siemens AS 488/TM is a cutting-edge solution in the realm of industrial automation and control. Designed specifically for high-performance applications, this device serves as a programmable logic controller (PLC) offering enhanced capabilities for process automation. The AS 488/TM stands out in the marketplace for its robust architecture, sophisticated features, and compatibility with various industrial protocols.

One of the pivotal features of the Siemens AS 488/TM is its integrated communication capabilities. It supports multiple communication protocols, such as Profibus, Profinet, and Ethernet/IP, facilitating seamless integration within diverse industrial environments. This flexibility ensures that the AS 488/TM can communicate with various devices, sensors, and actuators, providing a comprehensive solution for modern manufacturing needs.

In terms of processing power, the AS 488/TM is equipped with a high-performance CPU that can handle complex algorithms and data processing with ease. This enables the controller to manage intricate automation tasks, from simple control functions to complex multi-axis motion control. The device also comes with expandable I/O options, allowing users to tailor the system to meet specific application requirements. With a wide range of digital and analog inputs and outputs, the AS 488/TM ensures accurate monitoring and control of various processes.

Another notable characteristic of the AS 488/TM is its user-friendly programming interface. Siemens has developed the TIA Portal (Totally Integrated Automation Portal), a software platform that simplifies the programming and configuration of the PLC. This intuitive interface allows users to program the device using various programming languages, including Ladder Logic, Function Block Diagram, and Structured Text. The TIA Portal enhances productivity by providing simulation tools for testing and debugging applications before deployment.

The AS 488/TM also emphasizes safety and reliability. It complies with international safety standards and incorporates features that ensure safe operation in critical applications. Redundant power supplies and fail-safe mechanisms are integrated to minimize downtime and protect both personnel and equipment.

Moreover, the Siemens AS 488/TM is designed with future scalability in mind. As industries evolve and technology advances, the AS 488/TM can adapt to new requirements, ensuring a long service life and ongoing relevance in a rapidly changing landscape. Overall, the Siemens AS 488/TM is an impressive PLC that combines innovative features, robust technology, and flexible integration capabilities, making it an ideal choice for modern industrial automation systems.