DP extensions for AS 488/TM

Overview

Starting with the AS 488/TM system software M01.00, the ET 200M, ET 200U and ET 200B distributed I/O systems are explicitly released for the AS 488/TM as remote I/Os on the PROFIBUS-DP. Use of these systems on the AS 488/TM was supported by the DPAE/DPAA and DPBE/DPBE driver blocks right from the beginning. S5 and S7 formats could be used for the raw analog values.

Connection of other standard DP slaves from the product ranges of Siemens and other vendors was assured as far as communi- cation was concerned; however, support with respect to conver- sion of analog values and acquisition of diagnostics data could not be assured in all cases.

The DP extensions for AS 488/TM, which require the AS 488/TM system software M01.06 or M02.00, extend the AS x88/TM by the following functions:

Support of further DP ranges and devices

-ET 200S, ET 200X

-Links with DP/AS-i conversion (link 20 and link 65) as well as CP 342-2 communications processor for ET 200M for linking of the AS-I fieldbus

-IM 153-2 and IM 153-2 FO

-SIMATIC S7 CPU 315-2 DP and SIMATIC S5-95U

Additional DP4E/DP4A driver blocks with new types of format for analog values

-4-byte integers (long integers)

-S7/IEEE floating-point numbers

(only supported if at least the small PROFIBUS-PA license is present)

-S5 floating-point numbers

HMI driver block with server functions for the TP170B, OP170B, MP270 and MP370 panels based on Microsoft Windows

Increase in number of DP slaves per DP line to 122

The user documentation includes information and examples on configuring and diagnostics.

Mode of operation

Driver blocks

Driver

Description

name

 

 

 

DP4E

Input block for four input values as long integer, S7/IEEE

 

and S5 floating-point numbers, and conversion into TM

 

floating-point numbers

 

 

DP4A

Output block for four TM floating-point numbers following

 

previous conversion into long integer, S7/IEEE and S5

 

floating-point numbers

 

 

HMI

Downloadable block (version V3.0 onwards) with server

 

functions for operation of Windows-based TP170B and

 

OP170B panels and MP270 and MP370 multipanels

The DP4E/DP4A driver blocks support use of the COUNT mod- ule of ET 200S, amongst others.

The DP4E/DP4A driver blocks directly convert TM floating-point numbers and floating-point numbers in SIMATIC S5 format (KG format) so that S5 components or components from other vendors which support the KG format can be directly operated. If the AS 488/TM has a PROFIBUS-PA license, the direct ex- change of IEEE floating-point numbers is possible between AS 488/TM and the SIMATIC S7 station or the device from anoth- er vendor. Without a PROFIBUS-PA license for the AS 488/TM, the floating-point numbers must be converted on the S7 station or the device from another vendor into the KG format if they are to the transported via the DP nterface.

The maximum number of 122 DP slaves on a DP line can only be reached if each DP slave does not occupy more than 64 byte in- put data and 64 byte output data.

Ordering Data

 

Order No.

Program package "DP exten-

C79451-A3496-D900

sions for AS x88/TM"

 

comprising:

3.5" program diskettes

-Driver blocks (partially inte- grated in system program, partially downloadable)

-Extension of PROFIBUS-DP communications interface

-User documentation in Ger- man and English

-Initialization software for oper- ation of the second DP line

Product documentation in Ger- man and English

Note:

The system software M02.01 or M01.07 already supports the AS 488/TM as standard for the maximum number of 122 DP slaves per DP line as well as hot swapping of ET 200S and ET 200M with IM 153-2 or IM 153-2 FO.

The HMI driver block is not suitable for use of panels belonging to the older generation (e.g. OP37). These cannot be directly connected to the DP line of the AS 488/TM via their DP interface, but have to be linked, for example, via an intermediate S7-300 station with CPU 315-2DP. An example configuration is shown in the user documentation.

The program package "DP exten- sions for ASx88/TM" can be used for AS x88/TM from version M01.06 or M02.00 onwards

8/6

Siemens PLT 112 · 2002

Page 67
Image 67
Siemens manual DP extensions for AS 488/TM, Mode of operation, Driver blocks

AS 488/TM specifications

The Siemens AS 488/TM is a cutting-edge solution in the realm of industrial automation and control. Designed specifically for high-performance applications, this device serves as a programmable logic controller (PLC) offering enhanced capabilities for process automation. The AS 488/TM stands out in the marketplace for its robust architecture, sophisticated features, and compatibility with various industrial protocols.

One of the pivotal features of the Siemens AS 488/TM is its integrated communication capabilities. It supports multiple communication protocols, such as Profibus, Profinet, and Ethernet/IP, facilitating seamless integration within diverse industrial environments. This flexibility ensures that the AS 488/TM can communicate with various devices, sensors, and actuators, providing a comprehensive solution for modern manufacturing needs.

In terms of processing power, the AS 488/TM is equipped with a high-performance CPU that can handle complex algorithms and data processing with ease. This enables the controller to manage intricate automation tasks, from simple control functions to complex multi-axis motion control. The device also comes with expandable I/O options, allowing users to tailor the system to meet specific application requirements. With a wide range of digital and analog inputs and outputs, the AS 488/TM ensures accurate monitoring and control of various processes.

Another notable characteristic of the AS 488/TM is its user-friendly programming interface. Siemens has developed the TIA Portal (Totally Integrated Automation Portal), a software platform that simplifies the programming and configuration of the PLC. This intuitive interface allows users to program the device using various programming languages, including Ladder Logic, Function Block Diagram, and Structured Text. The TIA Portal enhances productivity by providing simulation tools for testing and debugging applications before deployment.

The AS 488/TM also emphasizes safety and reliability. It complies with international safety standards and incorporates features that ensure safe operation in critical applications. Redundant power supplies and fail-safe mechanisms are integrated to minimize downtime and protect both personnel and equipment.

Moreover, the Siemens AS 488/TM is designed with future scalability in mind. As industries evolve and technology advances, the AS 488/TM can adapt to new requirements, ensuring a long service life and ongoing relevance in a rapidly changing landscape. Overall, the Siemens AS 488/TM is an impressive PLC that combines innovative features, robust technology, and flexible integration capabilities, making it an ideal choice for modern industrial automation systems.