Teleperm m
Automation and Drives
Related catalogs
AS 488/TM automation systems
Introduction
AS 488/TM
Teleperm M Process Control System
Automation systems
Introduction
Teleperm M Process Control System
Overview
Engineering
System bus
Migration strategy
AS 488/TM
Non-migratable systems
Highlights
Classification in the Teleperm M system environment
Limitations in communication
Functions Highlights
Area of application
Commissioning
System architecture
System properties
System software
System architecture
System properties
Functions
AS 488/TM CPU
Technical Specifications Quantity breakdown
Optional function blocks
System software
User function blocks
Standard function blocks
Blocks for binary processing
Configuration
Listing of Teleperm M standard function blocks Data blocks
Blocks for analog and digital processing
AKE
PKM
PKF
AKS
Type Name Function Interface
Blocks for PLC/PLC coupling with PROFIBUS-AG/AG
Type Name Function For modules with Order No
Blocks for I/O modules with standardized display
Organization blocks
Test blocks
If 962-COM serial interface module
Commissioning
Commissioning terminal
Cable for connection of the commissioning terminal
Bus connection
Engineering with Prograf AS+
Technical Specifications Hardware requirements
Software requirements
Automation systems released for Prograf AS+/NT
Accessories
PC components ISA for connection to Teleperm M system bus
PC components PCI for connection to Teleperm M system bus
System architecture
AS 488 S cabinet system
AS 488 S Cabinet system
Scope of delivery of AS 488 S systems
Cabinet system
AS 488 S
AS 488 S cabinet system
System software
Power supply
Cables for connection of two I/O buses with versions 1
Connection to CS 275 system bus with versions 5 to
Log IK PI
Teleperm M 19 cabinets
6DS9 207-8AA
AS 488 K compact system
AS 488 K Compact system
Overview Ordering Data
Compact system
AS 488 K
AS 488 K compact system
Connection to CS 275 system bus
Teleperm M I/Os connection
Bus components for single CS
Bus components for redundant CS
Each 6DS4 400-8AB 6DS9 203-8CA
Introduction
AS 488 in Simatic design
Technical Specifications
AS 488 in Simatic design
Introduction
ET 200B
Coupling to other systems with DP interface
Coupling to PROFIBUS-PA
ET 200U
CPU
Central processing unit
Overview CPU
Monitoring
Power supply modules
PS 405 and PS 407 load power supplies
Backup battery
DP2-INI initialization C79451-A3496-D900
Connection of distributed I/Os
EXM 478 expansion module 6ES7 478-2AC00-0AC0
If 964-DP interface module
Connection to Teleperm M I/Os
Connection to CS Connection to PROFIBUS-TM
TPM 478 interface module 6ES7 478-2DA01-0AC0
EXM 478 expansion module
Packaging system
Overview UR2 rack
Migration rack
System software, documentation
Additional configuring tools
Simatic PCS 7 cabinet design
Cabinet packaging system
Simatic PCS 7 cabinet design
Options for the electrical design
Basic cabinet
Mechanical design
Electrical design
Hot swapping
Power supply
Load power supply for I/O modules
ET 200M I/O unit
AS 488/TM system unit
Simatic PCS 7 cabinet design
Migration packages
Migration of existing systems
Migration of existing systems
Migration of existing systems
General marginal conditions
AS 488 S migration package
Scope of delivery and services
Additive supplementary components and services
Migration packages
AS 488 S migration package
General marginal conditions/limitations
AS 488 K migration package
GWK-PAS-AS-UPAK488
AS 488 K migration package
MIG I migration rack
MIG II migration rack
Configuration possibilities for I/Os
MIG K migration rack
Retrofitting services
Check list prior to retrofitting
Configuring lists
Migratable Teleperm M modules in AS 488/TM
Migratable Teleperm M modules in AS 488/TM
Coupling modules
Explanations for the column „Remarks
Explanations for the column „Release
Binary calculation modules
Migration of existing systems
Connecting PROFIBUS-PA to AS 488/TM
Process I/Os
ET 200M packaging system
Process I/Os
Set of ribbon cables C79451-A3496-D2
Connecting Teleperm M I/Os
TBX 478 interface module
TBX 478 interface module 6ES7 478-2DX00-0AA0
Connecting Simatic I/Os
Interface module for connection to PROFIBUS-DP
Communication via the PROFIBUS-DP fieldbus
PROFIBUS-DP quantity breakdown
COM Profibus
Mode of operation
DP extensions for AS 488/TM
Driver blocks
ET 200M
ET 200M packaging system
Components for both packaging systems
Simple packaging system with bus connectors
ET 200M modules
Inputs, 8 outputs, extended
Temperature range Inputs, 16 outputs
Temperature range Inputs, 14 bit, 20 ms conver
SM 323 digital input/output modules Inputs, 8 outputs
Ex analog input/output modules EEx ib
Ex I/O modules
Ex digital input/output modules EEx ib
Intrinsically-safe equipment which can be connected
Function and communications modules
ET 200S
Configuration limits when used on AS
Configuration and parameterization
ET 200S
6ES7 134-4GB00-0AB0
6ES7 134-4FB00-0AB0
6ES7 134-4FB50-0AB0
6ES7 134-4LB00-0AB0
IP 262 closed-loop control mod- ule
ET 200X, ET 200U and ET 200B
ET 200U
ET 200B
Siwarex M
Configuration Siwa driver block
Teleperm M
Connecting PROFIBUS-PA to AS 488/TM
Properties and application features of the PROFIBUS-PA
Delivery forms
PROFIBUS-PA
Connection of PROFIBUS-PA using DP/PA coupler
Connection of PROFIBUS-PA using DP/PA link
Driver block Description
AS x88/TM-PA coupling soft 6DS5 130-8AA Ware, full license
Technical Specifications Ordering Data
Technical data DP/PA link IM DP/PA coupler Only
IM 157 interface module for 6ES7 157-0AA81-0XA0 DP/PA link
Process I/Os
CS-L2 bridge
Bus communication
Transmission systems
Bus communication
Bus connector
Electrical bus terminal
Optical link module
Transmission media
Optical bus terminal OBT for Profibus
TPM 478 interface module
Configuring
Remote bus cable with addi- tional armoring
Standard remote bus cable V45466-D21-B35
Length ..... m
In-house remote bus cable
CS-L2 bridge
CS-L2 bridge
PROFIBUS-TM
Configuration Station addresses
Performance data
CS-L2 bridge
Central processing unit
PS 405 load power supply, 10 a 6ES7 405-0KA01-0AA0
Connection to PROFIBUS-TM Connection to CS
If 964-DP interface module 6ES7 964-2AA01-0AB0
TPM 478 interface module
Ordering Data Overview
Introduction AG-AG coupling software Serial coupling
Data couplings with other systems
Coupling with systems from other vendors
Data couplings with other systems
Data couplings
10/2
AG/AG coupling with Simatic S5/S7 central controllers
System couplings
AG-AG coupling software
10/3
SDA
10/4
PROFIBUS-AG/AG
AG/AG coupling software 6DS5 124-1AA
Transmission rate Max. cable length
Direct couplings
Serial coupling
10/5
10/6
Appendix
11/2
Appendix
Software licenses
Software
Information and order option
Internet and on CD-ROM
11/3
Training Courses in the Training Center Karlsruhe
Internet, Training
11/4
Internet
11/5
Order No. index