This catalog is out of date, see note on page 3

Bus communication

CS-L2 bridge

Central processing unit

The inputs and outputs are electrically isolated. The module electronics (ASIC) is protected against overvoltages by appro- priate circuitry measures.

The digital inputs comprise 8 channels organized in groups of 4 x 2 channels. The current consumption is 8.5 mA with an input level of DC 24 V.

An input delay of 500 ms or 3 ms can be parameterized for all input channels together.

The cable length is:

• unshielded 200 m (for 500 ms) or 600 m (for 3 ms)

• shielded 1000 m.

The digital outputs also comprise 2 x 4 channels. With DC 24 V, the max. output current is 100 mA. The outputs are protected against short-circuit by an electronic fuse.

A 25-contact Sub-D socket is used as the interface.

Overview

CPU 486-3

The CPU 486-3 is equipped with an Intel Pentium 75-MHz pro- cessor.

The front panel of the rugged, compact plastic housing contains:

IF 962-COM serial interface module

The IF 962-COM serial interface module is required to connect a commissioning terminal to the CS-L2 bridge. The module is in- serted into a prepared slot in the CPU 486-3.

LEDs for status and fault display

Operating mode switch

Slot for a memory card from which the coupling software and bus parameters are loaded into the main memory when start- ing up

2 slots for interface modules

Design

Memory module (set with 2 x 8 Mbyte)

The CPU 486-3 used in the CS-L2 bridge is supplied with an integral RAM. The module used as the main memory comprises a set with 2 x 8-Mbyte RAMs. The complete set must always be inserted.

I & C monitoring

I & C monitoring functions can be implemented using the IF 961-DIO interface module for digital input/output.

The interface module is inserted in the EXM 478-3 module of the AS 488 automation system.

The IF 961-DIO can be used to record I & C signals e.g. for

door contact

excess temperature

monitoring of optical link module OLM

and to activate a cabinet lamp or horn.

Cable monitoring, e.g. to detect an open-circuit, is not possible.

Ordering Data

 

Order No.

 

 

CPU 486-3 central module

6ES7 486-3AA00-0AB0

with Pentium 75 MHz CPU, 2 slots

 

for interface modules,

 

2 standard slots wide

 

IF 961-DI0 interface module

6ES7 961-1AA00-0AC0

Digital input/output for I & C moni-

 

toring functions

 

IF 962-COM serial interface

6ES7 962-3AA00-0AC0

module

 

for commissioning terminal,

 

with 2 RS 232 interfaces

 

 

 

Siemens PLT 112 · 2002

9/9

Page 90
Image 90
Siemens AS 488/TM manual Central processing unit

AS 488/TM specifications

The Siemens AS 488/TM is a cutting-edge solution in the realm of industrial automation and control. Designed specifically for high-performance applications, this device serves as a programmable logic controller (PLC) offering enhanced capabilities for process automation. The AS 488/TM stands out in the marketplace for its robust architecture, sophisticated features, and compatibility with various industrial protocols.

One of the pivotal features of the Siemens AS 488/TM is its integrated communication capabilities. It supports multiple communication protocols, such as Profibus, Profinet, and Ethernet/IP, facilitating seamless integration within diverse industrial environments. This flexibility ensures that the AS 488/TM can communicate with various devices, sensors, and actuators, providing a comprehensive solution for modern manufacturing needs.

In terms of processing power, the AS 488/TM is equipped with a high-performance CPU that can handle complex algorithms and data processing with ease. This enables the controller to manage intricate automation tasks, from simple control functions to complex multi-axis motion control. The device also comes with expandable I/O options, allowing users to tailor the system to meet specific application requirements. With a wide range of digital and analog inputs and outputs, the AS 488/TM ensures accurate monitoring and control of various processes.

Another notable characteristic of the AS 488/TM is its user-friendly programming interface. Siemens has developed the TIA Portal (Totally Integrated Automation Portal), a software platform that simplifies the programming and configuration of the PLC. This intuitive interface allows users to program the device using various programming languages, including Ladder Logic, Function Block Diagram, and Structured Text. The TIA Portal enhances productivity by providing simulation tools for testing and debugging applications before deployment.

The AS 488/TM also emphasizes safety and reliability. It complies with international safety standards and incorporates features that ensure safe operation in critical applications. Redundant power supplies and fail-safe mechanisms are integrated to minimize downtime and protect both personnel and equipment.

Moreover, the Siemens AS 488/TM is designed with future scalability in mind. As industries evolve and technology advances, the AS 488/TM can adapt to new requirements, ensuring a long service life and ongoing relevance in a rapidly changing landscape. Overall, the Siemens AS 488/TM is an impressive PLC that combines innovative features, robust technology, and flexible integration capabilities, making it an ideal choice for modern industrial automation systems.