Siemens manual Switching on the HC15, Switching off the HC15, Registering to the Network

Models: HC15

1 31
Download 31 pages 46.62 Kb
Page 16
Image 16
3.2Switching on the HC15

Getting Started with HC15

Confidential / Preliminary

s

3.2Switching on the HC15

The HC15 can be started by pressing the IGT key of the DSB75. Please wait approximately 2 seconds before using the module, for example before entering AT commands.

Disconnecting and plugging the USB cable during operation is not supported.

3.3Switching off the HC15

To shut down the HC15 module, enter the AT^SMSO command. This enables the ME to save all data and perform an orderly shutdown.

AT^SMSO

The ME switches off.

OK

 

 

 

The HC15 module can also be switched off by using the IGT line as described in [1] (see AT^SCFG) and [1] (see section “Configuring the IGT Line for Use as ON/OFF Switch”).

3.4Registering to the Network

Make sure to operate the HC15 always with the UICC card inserted in the DSB75 card reader and a valid SIM PIN entered. This is because most AT commands require SIM PIN authentication.

Write command: AT+CPIN=<pin>[, <new pin>]

at+cpin?

Entering the SIM PIN.

+CPIN: SIM PIN

 

OK

 

at+cpin=1234

 

OK

 

at+cpin?

 

+CPIN: READY

 

OK

 

 

 

HC15_startup_v01

Page 16 of 31

2007-01-22

Page 16
Image 16
Siemens manual Switching on the HC15, Switching off the HC15, Registering to the Network, Getting Started with HC15