Information about Software 33
Adding a New CMU Equipped with SPARC64 VII as a New Domain
1. Log in to the XSCF on an account with platform administrative privileges.
2. Use the showstatus(8) command to confirm that a component in Faulted or
Deconfigured status doesn't exist.
If no failures found, the following message appears: "No failures found in
System Initialization." In case of other messages, contact a service engineer
before proceeding to the next step.
3. Change the key position on the operator panel from Locked to Service.
4. Collect an XSCF snapshot to archive system status prior to upgrade.
This will be help in case any problem occurred in this procedure.
5. Update the XCP version to 1071 or later.
Before updating the XCP, be sure to see “Updating to XCP” on page3.
For the XCP updating procedures, see the SPARC Enterprise
M4000/M5000/M8000/M9000 Servers XSCF User’s Guide.
6. After updating the XCP, reset the XSCF.
7. After resetting the XSCF, log in to the XSCF again.
8. Mount the CPU module (CPUM) on the CMU for add-on.
For the procedure, see the description about the CPU module installation in Section
6.4.1, "Replacing a CPU module" in the SPARC Enterprise M8000/M9000 Servers
Service Manual.
9. Mount the CMU, described in step 8, on the server.
a. Executing the addfru(8) command and select “CMU/IOU” from the maintenance
menu.
b. Perform the operation according to the instructions displayed in the
maintenance menu, referring to “6.2 Active Replacement and Hot Replacement”
in SPARC Enterprise M8000/M9000 Servers Service Manual.
XSCF> showstatus
XSCF> snapshot -t user@host:directory
XSCF> rebootxscf
XSCF> addfru