34 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1072 • September 2008
Note – Do not fail to execute the diagnosis of newly mounted CMU in the maintenance
menu of addfru(8) command.
10. Confirm that the mounted CPU module has been recognized by the server, and the
error indicator asterisk (*) is not displayed.
11. Confirm no abnormality occurred by using showlogs error -v and
showstatus(8) commands.
If you encounter any hardware abnormality of the XSCF contact a service engineer.
12. Move the key position on the operator panel from Service to Locked.
13. Sets the following for t he CMU.
Set up XSB.
Set up the domain
Set up the CPU operational mode of the domain.
For each setting, see the SPARC Enterprise M4000/M5000/M8000/M9000 Servers XSCF
User’s Guide.
14. Use the setdomainmode(8) command, disable the autoboot function of the
domain.
For detail, see the SPARC Enterprise M4000/M5000/M8000/M9000 Servers XSCF User’s
Guide.
15. Power on the domains.
16. Confirm that the target domain has been correctly started.
17. Confirm no abnormality occ urred by using showlogs error -v and
showstatus(8) commands.
If you encounter any hardware abnormality of the XSCF contact a service engineer.
XSCF> showhardconf -M
XSCF> showlogs error -v
XSCF> showstatus
XSCF> poweron -d domain_id
XSCF> showlogs power
XSCF> showlogs error -v
XSCF> showstatus