Siemens Mux_guide_v06 manual Power saving control PSC, Type Bit, Value octet Length=1 Bit

Models: Mux_guide_v06

1 36
Download 36 pages 45.74 Kb
Page 30
Image 30

Multiplexer User's Guide

Confidential / Released

s

mobile

4.3.10 Power saving control (PSC)

The power saving control message uses the following type field octet:

Type:

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

1

C/R

0

0

0

0

1

0

Figure 12: Power Saving Control (PSC)

C/R bit: Indicates whether the sequence is a command or a response.

Length: The length byte contains the value 0 (no value octet) or 1 (one value octet).

Value octet (Length=1)

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

P1

P2

P3

P4

0

0

0

0

The P-bits are defining the parameter value.

In commands:

Bit 1

Bit 2

Bit 3

Bit 4

Description

0

0

0

0

Switches to the same mode as without a

 

 

 

 

value octet

1

0

0

0

Switches into full functionality mode, like

 

 

 

 

AT+CFUN=1

0

1

0

0

Switches into NON-CYCLIC SLEEP mode,

 

 

 

 

like AT+CFUN=0

1

1

0

0

Switches into CYCLIC SLEEP mode, like

 

 

 

 

AT+CFUN=5

0

0

1

0

Switches into CYCLIC SLEEP mode, like

 

 

 

 

AT+CFUN=6

1

0

1

0

Switches off, like AT^SMSO

 

 

 

 

 

0

1

1

0

Resets, like AT+CFUN=1,1

 

 

 

 

 

1

1

1

0

Switches into CYCLIC SLEEP mode, like

 

 

 

 

AT+CFUN=7

0

0

0

1

Switches into CYCLIC SLEEP mode, like

 

 

 

 

AT+CFUN=8

All wake up events and details of the CYCLIC and NON-CYCLIC SLEEP mode are specified in [2].

In responses:

Bit 1

Bit 2

Bit 3

Bit 4

Description

0

0

0

0

Failure

1

0

0

0

Success

Mux_guide_v06