Installing and Starting the Ethernet CP with STEP 7

Table 2-1 Settings in the “Options” Tab , continued

Option

Meaning / Effect

 

 

S Replace Module without PG

With this option, you can have the configuration data of the CP stored

 

on the CPU. If you then replace CP, the configuration data for the

 

new CP are downloaded automatically from the CPU when the CP is

 

started up.

 

If you select this option, the configuration data are stored long-term

 

on the CPU instead of in the EPROM of the CP. Remember, however,

 

that long-term storage on the CPU is only safe from power outages if

 

the CPU is protected by battery backup or by using an S7 Memory

 

Card.

 

 

Note

 

 

If you store the configuration data on the CPU, please read the note

 

 

below.

 

 

The following functions do not modify the configuration data on the

 

 

CPU:

 

 

S Reset module memory

 

 

S Resetting to factory settings

 

 

S Assigning an IP address1) (using the target system selection in

 

 

the SIMATIC Manager or the properties dialog in HW Config or

 

 

NetPro)

 

 

If you subsequently upload the configuration data from the CPU to a

 

 

PG you will always object the configuration data that were previously

 

 

on the CP (with parameters, connections, IP address).

 

 

1) Note: You should only use the assign IP address function during

 

 

commissioning; in other words, before downloading the configuration

 

 

data.

 

 

 

S

Ethernet Profile for

Select this profile if you use fault-tolerant communication in your

 

Fault-Tolerant Connections

system. Fault-tolerant communication means that Industrial Ethernet

 

 

is designed with redundancy and that you have configured

 

 

fault-tolerant S7 connections.

 

 

If you select the Ethernet profile for fault-tolerant connections here,

 

 

the time response of the S7 connections is adapted. As a result,

 

 

breakdowns of a connection are detected more quickly and the

 

 

failover to redundant connections is faster.

 

 

 

 

 

Note

 

 

Select the Ethernet profile for fault-tolerant connections only when

 

 

you actually use fault-tolerant S7 connections. Otherwise you must

 

 

expect your system to be more susceptible to problems since, for

 

 

example, the number of transfer or connection establishment

 

 

attempts is reduced compared with non-redundant systems.

 

 

 

S

Individual Network Settings

Here, you can make fixed network settings, when necessary. As

 

 

default, “Automatic Setting” is selected and this setting generally

 

 

guarantees problem-free communication in most situations.

 

 

If problems occur in communication (for example, when connections

 

 

are not established or when there are often disturbances on the

 

 

network), the reason may be that the selected or automatic network

 

 

settings are not suitable. You can then select a network setting to suit

 

 

your network configuration.

 

 

 

SIMATIC NET NCM S7 for Industrial Ethernet

59

Release 6/2003

C79000–G8976–C129–07

Page 59
Image 59
Siemens NCM S7 appendix Cpu

NCM S7 specifications

Siemens NCM S7, which stands for Siemens Network Control Module for the S7 series, represents a significant advancement in industrial automation technology. This robust control system is designed to enhance productivity and efficiency in various manufacturing processes. Its primary purpose is to facilitate seamless communication between field devices and higher-level control systems, ensuring that processes run smoothly and effectively.

One of the main features of the Siemens NCM S7 is its exceptional connectivity. The module is equipped with integrated network capabilities that support various communication protocols such as Ethernet, Profibus, and Profinet. This versatility allows it to work with a wide variety of devices, enabling data exchange across different automation levels. The ability to connect to cloud services is another standout feature, allowing users to access real-time data remotely for monitoring and analytics.

The NCM S7 also boasts advanced data processing capabilities. With powerful processing units, it can execute complex control algorithms and manage large volumes of input and output data in real time. This is essential for industries that require precise control over their processes, such as automotive, food and beverage, and pharmaceuticals. The system’s high-speed memory and processing speed ensure that it can handle demanding tasks without lag.

In terms of technology, the Siemens NCM S7 leverages state-of-the-art cybersecurity features. As industrial control systems increasingly become targets for cyber threats, the NCM S7 incorporates advanced security protocols to safeguard sensitive data and ensure the integrity of the control processes. This includes features such as secure communication channels and user authentication.

Another key characteristic of the NCM S7 is its flexibility. The system can be easily scaled and adapted to meet the specific needs of various applications. Users can increase the number of input/output channels or integrate additional modules without significant downtime. This adaptability makes the NCM S7 an ideal choice for both small-scale operations and large industrial environments.

Moreover, the user-friendly interface simplifies configuration and programming tasks, allowing engineers and technicians to set up and troubleshoot the system with ease. Siemens has also invested in comprehensive support and training resources to help users maximize the system’s potential.

In conclusion, the Siemens NCM S7 stands out as a pivotal element in modern industrial automation. With its robust connectivity, advanced data processing capabilities, cybersecurity features, and flexibility, it empowers businesses to optimize their production processes and embrace the future of Industry 4.0.