Status and fault/error displays

The CPU has the following LED displays:

Slot for the SIMATIC Micro Memory Card (MMC)

A SIMATIC Micro Memory Card (MMC) is used as a memory module for the CPU 31xC. The MMC can be used as a load memory and as a transportable data carrier. The MMC must be plugged in before the CPU can be operated because the CPUs 31xC do not have an integrated load memory.

Mode selector

The mode selector can be used to choose the current operating mode of the CPU. The mode selector is designed as a toggle switch with 3 positions.

Positions of the mode selector

The positions of the mode selector are explained in the same sequence as they occur on the CPU:

Position

Description

Comments

RUN

RUN mode

The CPU is processing the user program

STOP

STOP mode

The CPU is not processing a user program

MRES

Memory Reset

Button position of the operating mode switch for a memory

 

 

reset of the CPU. A CPU memory reset requires a specific

 

 

operating sequence (refer to the Installation Manual,

 

 

Chapter Commissioning)

 

 

 

 

 

 

 

 

 

Foreword

Notes

Hardware configuration

STEP 7 program

Testing

 

 

 

 

 

 

 

T I A Training Document

 

Page 8 of 25

 

Module

 

 

 

 

A5

Issue date: 02/2008

 

 

Programming the CPU 314C-2DP