SIEMENS se5880 Ethernet Security Router

Chapter 4 User Setup

User’s Guide

Access Control

 

 

Access Control

Restrict administrative control of the router to a specific set of IP addresses on the Access Control page. Each remote access method (Telnet, Web, and SNMP) can be configured separately.

To set Access Control parameters:

1.Click Access Control from the left navigation pane of the Router Information page. This displays the Access Control page.

2.Optionally, select one or more of the following remote access methods to enable that method of remote access. A check in the box next to the method specifies enabled. If disabled, any access restriction specification is disregarded.

Telnet

Web

SNMP

3.For each remote access method selected, specify any access restrictions. This can be one of the following:

No access restrictions:

Remote access method is enabled and not restricted. This setting allows access from all hosts.

Allowed from LAN:

Limits access to the host from the LAN.

4.Optionally select Allow System Logging to Syslog Servers. If selected, specify any access restrictions. This can be one of the following:

No access restrictions:

System Logging is not restricted. This setting allows access from all servers.

Allowed from LAN:

Limits access for System Logging to servers on the LAN.

5.Click Save and Reboot.