SIEMENS se5880 Ethernet Security Router

Chapter 6 Security Setup

User’s Guide

Stateful Firewall

 

 

Configure Stateful Firewall

To configure the Stateful Firewall:

1.Click Stateful Firewall from the left navigation pane of the Router Information page. This displays the Stateful Firewall Configuration page.

2.For Firewall Status, select On or Off to turn Stateful Firewall on or off.

3.For Watch Setting, select On or Off to control whether or not messages are printed to the console whenever a packet is accepted or dropped.

4.In Dropped Packet Threshold Setting, specify the number of packets per second that must be dropped before a message is logged to the console. The default value is 200 packets per second.

5.In UDP Packet Threshold Setting, specify the number of UDP Packets per second that can be received. When this number is exceeded, the firewall blocks any subsequent UDP packets. The default value is 1000 UDP packets per second.

6.In ICMP Ping Packet Threshold Setting, specify the number of ICMP Ping Packets per second that can be received. When this number is exceeded, the firewall blocks any subsequent ICMP ping packets. The default value is 1000 ICMP Ping Packets per second.

7.In SYN Packet Threshold Setting, specify the number of SYN requests per second that can be received. When this number is exceeded, the firewall blocks any subsequent SYN requests. The default value is 200 SYN packets per second.

8.Click Apply.

SIEMENS

58

Page 64
Image 64
Siemens se5880 manual Configure Stateful Firewall