PROGRAM INSTRUCTIONS (cont)

2. Depress MODE (S1) switch once.

The text ���� followed by the current value of Alarm Set Point High 1 (SPH1) will be displayed. Use S2 and S3 to set Alarm Set Point High 1 to the desired value. Proceed to Step 3 to set Alarm Setpoint Low 1 (SPL1) or depress S4 to exit MODE sequence. If S4 is depressed, the new value for SPH1 will be saved in non-volatile NOVRAM memory.

3. Depress MODE (S1) switch once.

The text ����� followed by the current value of Alarm Set Point Low

1 will be displayed. Repeat Step 2 to set Alarm Set Point Low 1 to the desired value. Proceed to Step 4 or depress S4 to exit.

4.Depress MODE (S1) switch once.

The text ���� followed by the current value of Alarm Set Point High 2 will be displayed. Repeat Step 2 to set Alarm Set Point High 2 to the desired value. Proceed to Step 5 or depress S4 to exit.

5.Depress MODE (S1) switch once.

The text ���� followed by the current value of Alarm Set Point Low 2 will be displayed. Repeat Step 2 to set Alarm Set Point Low 2 to the desired value. Proceed to Step 6 or depress S4 to exit.

6.Depress MODE (S1) switch once.

The text �� followed by the current value of Alarm Hysteresis High will display. Repeat Step 2 to set Hysteresis High to the desired value. The maximum value for HH is 99 counts. Proceed to Step 7 or depress S4 to exit.

Page 11

Page 12
Image 12
Sierra 951 instruction manual