Simer Pumps 2115 owner manual Repair Parts / Troubleshooting, Anti-Airlock 4 Hole

Models: 2115

1 15
Download 15 pages 40.04 Kb
Page 4
Image 4
Repair Parts / Troubleshooting

Repair Parts / Troubleshooting

4

7

6 Anti-AirlockREPAIR PARTSAssemble Screen and Shield as shown.

5

TROUBLESHOOTINGAnti-Airlock

4  Risk of electrical shock and sudden start.Manual background Hole

3

2

1

5635 0607

REPAIR PARTS

Key

Part Description

Qty.

Part No.

1

Base

1

PS70-83

2

Screen

1

PS8-6P

3

Shield

1

PS70-3P

4

Impeller

1

PS5-25P

5

Motor

1

**

6

90° Garden Hose Adapter

1

PS74-78

7

Power Cord

1

PS17-1505

 

 

 

 

NOTICE: To purchase a check valve, call Customer Service at 1-800-365-6832 and order part number PW73-63.

**If motor fails, replace entire pump.

• Not Illustrated.

Insert Screws through base. (Base omitted for clarity)

Orient Part Number with

Anti-Airlock

Hole

Anti-Airlock Hole as shown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tighten 1stManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

3rd2nd

Assemble Screen and Shield as shown.

TROUBLESHOOTING

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Risk of electrical shock and sudden start.

Disconnect electrical power to pump before attempting to troubleshoot or work on it.

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t

Blown fuse

If blown, replace with fuse of proper size

start or run

Low line voltage

If voltage under recommended minimum, check size of wiring

 

 

from main switch on property. If OK, contact power company.

 

Defective motor

Replace pump

 

Impeller

Remove base and screen, locate source of binding

 

 

 

Pump operates

Low line voltage

Call power company

but delivers little

 

 

or no water

Something caught in impeller

Clean out impeller

 

Small diameter garden hose

Use larger diameter garden hose or 1" flexible pipe. Eliminate any

 

or long discharge line

excess hose. Short hoses work best

 

Check valve installed without

Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump

 

vent hole

discharge & check valve

 

Air lock

Turn off pump for a few seconds, clean out anti-airlock hole and restart pump

 

Coils or bends in hose

Straighten hose

 

 

 

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867