Impeller Replacement | 8 |
First: Turn off power to the pump, disconnect the discharge piping, and lift the pump out of the sump BY THE HANDLE ON TOP OF THE MOTOR (not by the cord).
Step 1: Remove the three screws holding the motor to the base and lift the motor off the base.
PS5- |
35P |
4831 0205
Step 2: Hold the motor shaft with a screwdriver and unscrew the impeller as shown.
NOTE: The impeller has a
PS5- |
35P |
4832 0205
Step 3: Thread the new impeller onto the motor shaft as
shown (left-hand thread – tightens to the left ).
Step 4:
Last: Run the pump through one complete cycle after it is assembled and reinstalled. It should operate correctly and you should not hear any sounds of scraping or dragging from the pump.
For parts or assistance, call Simer Customer Service at