Slant/Fin S-150 Sentry, Burners Pilot Burner Access Door Gas Valve, Installation Requirements

Models: SX-150 SX-210 S-150

1 20
Download 20 pages 11.1 Kb
Page 3
Image 3
Burners

Sentry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approx.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(inches)

 

 

 

 

 

 

 

 

 

 

 

 

Total Wt.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler

 

 

No. of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

Water (lb.)

 

 

 

 

 

 

 

Model

 

 

Sect.

 

 

 

 

A

 

 

 

 

B

 

 

 

C

 

 

 

 

D

 

 

 

 

E

 

 

 

F

 

 

 

 

 

CHIMNEY RECOMMENDATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(max)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT:15 ft. (minimum) from draft

 

S-34

 

2

 

 

 

818"

 

 

1458"

 

 

4

 

 

 

33"

 

 

 

 

 

 

 

 

614"

190

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hood skirt to top of chimney.

 

S-60

 

3

 

 

1118"

 

 

1758"

 

 

4

 

 

 

37"

 

 

 

 

412"

 

26"

 

 

 

614"

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSIDE DIAMETER: Same as dimen-

 

S-90

 

4

 

 

1418"

 

2058"

 

5

 

 

 

37"

 

 

 

 

512"

 

 

2512"

 

 

614"

310

 

 

sion C (or larger).

 

S-120

 

5

 

 

1718"

 

 

2358"

 

 

6

 

 

 

37"

 

 

 

 

712"

 

25"

 

 

 

614"

365

 

 

NOTE: Larger chimney may be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

required if two or more boilers or a boil-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-150

 

6

 

 

2018"

 

2658"

 

7

 

 

 

37"

 

 

 

 

812"

 

 

2412"

 

 

814"

425

 

 

er and another appliance are vented to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a single chimney.

 

SX-150

 

6

 

 

2018"

 

 

2658"

 

 

6

 

 

 

5112"

 

 

1012"

 

 

1078"

 

 

614"

425

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slant/Fin supplies vent dampers by

 

SX-180

 

7

 

 

2318"

 

2958"

 

7

 

 

 

5234"

 

12"

 

 

 

1078"

 

 

814"

485

 

 

several manufacturers. Some are

 

SX-210

 

8

 

 

2618"

 

 

3258"

 

 

7

 

 

 

5234"

 

 

1312"

 

 

1078"

 

 

814"

545

 

 

smaller than the indicated “G maxi-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mum”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice

 

 

 

 

 

 

 

 

 

 

Orifice Sizes

for High Altitudes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Includes 4% Reduction for Each 1000 Feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler

 

 

Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elevation - Feet

 

 

 

 

 

 

 

 

 

 

Sea

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

Type

 

Level

2000

 

3000

 

 

4000

 

5000

 

 

6000

 

7000

 

8000

9000

10000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-34

 

 

Natural

 

47

 

 

48

 

 

48

 

 

 

49

 

 

49

 

 

 

49

 

 

50

 

50

51

51

 

 

 

 

 

 

Propane

56

 

 

56

 

 

56

 

 

 

57

 

 

57

 

 

 

57

 

 

58

 

59

59

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-60 thru S-150 and

 

 

Natural

 

50

 

 

51

 

 

51

 

 

 

51

 

 

51

 

 

 

52

 

 

52

 

52

53

53

 

 

SX-150 thru SX-210

 

 

Propane

57

 

 

 

58

 

 

59

 

 

 

59

 

 

60

 

 

 

60

 

 

61

 

62

63

63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice indicated for sea level above are factory installed in boiler unless otherwise specified by the local authority. See III page 10 for burner input adjustment.

Base Assembly Sentry Boiler

Burners

Pilot

Burner

Access

Door

Gas Valve

INSTALLATION REQUIREMENTS

The installation must conform to the requirements of the authority having jurisdiction or, in the absence of such requirements, to the National Fuel Gas Code, ANSI Z223.1-latest edition.

This installation must also conform to the additional requirements in this Slant/Fin Instruction Book.

NATURAL GAS-FIRED BOILER LOCATION

Provide a level, solid foundation for the boiler. Location should be as near as possible to chimney or outside wall so that the flue pipe from boiler is short and direct.

The location should also be such that the gas ignition system com- ponents are protected from water (dripping, spraying, rain, etc.) during appliance operation and service (circulator replacement, condensate trap, control replacement, etc.).

BOILER FOUNDATION

A. Provide a solid, level foundation, capable of supporting the weight of the boiler filled with water, and extending at least 2" past the jacket on all sides. See dimensions of boiler, page 2.

B. For installation on non-combustible floors only. The Combustible Floor Kit part number printed on the boiler rating plate is the only one to be used when installing on combustible floors. The boiler must not be installed on carpeting.

C. If boiler is to be located over buried conduit containing electric wires or telephone cables, consult local codes or the National Board of Fire Underwriters for specific requirements.

Page 3
Image 3
Slant/Fin S-150, SX-210 Sentry, Burners Pilot Burner Access Door Gas Valve, Installation Requirements, Boiler Foundation