“S” AND “SX” MODELS SENTRY® HOT WATER MODELS
INSTALLATION AND OPERATING INSTRUCTIONS
CONTENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,3 Installation Requirements:
Boiler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Boiler Foundation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chimney Requirements . . . . . . . . . . . . . . . . . . . . . . . . 4
Minimum Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Draft Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Vent Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Vent Damper Installation . . . . . . . . . . . . . . . . . . . . 5,6,7
Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Electrical Controls and Wiring . . . . . . . . . . . . . . . . . . . 8
Boiler Room Air Supply and Ventilation . . . . . . . . . . . . 8
Water Piping at Boiler . . . . . . . . . . . . . . . . . . . . . . . . . 8
Operating Instructions:
Filling and Venting Water Systems. . . . . . . . . . . . . . . . 8 Initial Start, Safety and Lighting Instructions . . . . . 9,10 Burner Adjustment, Checking Gas Input . . . . . . . 10,11
Care and Maintenance
General Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . 11 Water Level Check . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Annual Inspection and Cleaning . . . . . . . . . . . . . . . . 12 Safety Check for Control Systems . . . . . . . . . . . . . . . 12 Protection from Freezing/Water Treatment. . . . . . . . . 12 Keeping Area Clear . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sequence of Operations . . . . . . . . . . . . . . . . . . . . . . . . . 13 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14,15 Pump or Valve Zoning of Water Boilers . . . . . . . . . . . . . 16 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Piping a
IMPORTANT
READ ALL OF THE FOLLOWING WARNINGS AND
STATEMENTS BEFORE READING THE
INSTALLATION INSTRUCTIONS
WARNING
LIQUEFIED PETROLEUM (L.P.)
PROPANE GAS-FIRED BOILERS
Installation location ONLY as permitted in paragraph enti- tled "LIQUEFIED PETROLEUM (L.P.) PROPANE GAS- FIRED BOILER LOCATION" on page 4 of this instruction book.
The above warning does not apply to NATURAL gas- fired boilers.
The installation must conform to the requirements of the authority having jurisdiction or, in the absence of such requirements, to the National Fuel Gas Code, ANSI
In addition, where required by the authority having jurisdic- tion, the installation must conform to American Society of Mechanical Engineers Safety Code for Controls and Safety Devices for Automatically Fired Boilers, No.
This manual must be left with owner and should be hung on or adjacent to the boiler for reference.
WARNING
This boiler, gas piping and accessories must be installed, connected, serviced and repaired by a trained, experi- enced service technician, familiar with all precautions required for
Heating Contractor
Boiler Model Number
Address
Boiler Serial Number
Phone Number
Installation Date
Printed in U.S.A. 605 | PUBLICATION |
Part No. | Rev. N |