Smeg A2-5 Final Operations, Burner and nozzle characteristics table, Burners, Rated, capacity

Models: A2-2 A2-5

1 30
Download 30 pages 17.92 Kb
Page 8
Image 8
3.2 Burner and nozzle characteristics table

Instructions for the installer

3.2 Burner and nozzle characteristics table

 

 

 

Rated

 

 

 

 

 

LPG – G30/G31 28/37 mbar

 

 

 

Burner

 

heating

 

 

 

 

 

 

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

By-pass

 

 

Reduced

 

Flowrate

 

 

Flowrate

 

 

 

 

 

 

diameter

 

mm

 

 

flowrate

 

g/h G30

 

 

g/h G31

 

 

 

 

 

 

1/100 mm

 

1/100

 

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.05

 

50

 

30

 

360

 

 

76

 

 

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi rapid

1.8

 

65

 

33

 

450

 

 

131

 

 

129

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid

3

 

85

 

45

 

750

 

 

218

 

 

215

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple crown

3.3

 

91

 

68

 

1600

 

240

 

 

236

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated heating

 

 

 

Natural gas – G20 20 mbar

 

 

 

Burner

 

capacity

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

 

 

 

 

Reduced

 

 

 

 

 

 

 

 

 

diameter

 

 

 

 

 

flowrate

 

 

 

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

1.05

 

 

 

 

72

 

 

 

 

360

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi rapid

 

1.8

 

 

 

 

97

 

 

 

 

450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid

 

3

 

 

 

 

115

 

 

 

 

750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple crown

 

3.5

 

 

 

 

133

 

 

 

 

1600

 

 

 

3.3Arrangement of burners on cooking hob

BURNERS

1 Auxiliary

2 Semi rapid

3 Rapid

4 Ultra rapid

5 Ultra rapid

4. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

After adjustment to a different kind of gas from the one for which the cooker has been tested, replace the plate inside the storage compartment with one corresponding to the new kind of gas. This plate can be obtained from your nearest Authorised Assistance Centre.