Smeg A2-2, A2-5 manual Ventilation requirements, Instructions for the installer

Models: A2-2 A2-5

1 30
Download 30 pages 17.92 Kb
Page 5
Image 5
For operation on 380-415V3N∼: use an

Instructions for the installer

For operation on 380-415V3N: use an

H05RR-F-type five-core cable (5 x 1.5 mm2).

For operation on 380-415V2N: use an

H05RR-F-type four-core cable (4 x 1.5 mm2).

For operation on 220-240V: use an

H05RR-F-type three-core cable (3 x 2.5 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.

2.2 Ventilation requirements

The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 1989.

1.All rooms require an opening window or equivalent, and some rooms will require a permanent vent as well.

2.For room volumes up to 5 m3 an air vent of 100 cm2 is required.

3.If the room has a door that opens directly to the outside, and the room exceeds 1 m3 no air vent is required.

4.For room volumes between 5 m3 and 10 m3 an air vent of 50 cm2 is required.

5.If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should be consulted to determine the air vent requirements.

6.This appliance must not be installed in a bed sitting room of less than 20 m3

or in a bathroom or shower room.

Windows and permanent vents should therefore not be blocked or removed without first consulting a Corgi gas installer.

Failure to install appliances correctly is dangerous and could lead to prosecution.