5.2Adjusting for bottled gas

Instructions for the Installer

5.2Adjusting for bottled gas

Undo the screw A and push the support B fully down. Remove the nozzle C with a spanner and fit the suitable one following the instructions in the tables referring to the type of gas to be used. The nozzle must not be tightened with a torque of more than 3 Nm. Return the support B to its original position, so that the nozzle C is perfectly covered.

Regulate the air flow by moving the Venturi pipe D until the distance “X” stated in point "5.5 Adjusting the primary air flow” is obtained and secure it with the screw A. When the adjustments are complete, restore the seals with wax or an equivalent material.

Nominal

BurnerheatBottled gas – G30/G31 30/37 mbar capacity

(kW)

 

Semi rapid (1)

 

1.7

 

 

 

 

 

 

 

 

 

Rapid (2)

 

2.9

 

 

 

 

 

 

Ultra-Rapid (3)

 

4.2

 

 

 

 

 

 

Nozzle

 

By-pass

 

Reduced

 

Capacity

 

Capacity

diameter

 

mm

 

heat

 

g/h G30

 

g/h G31

1/100 mm

 

1/100

 

capacity

 

 

 

 

 

 

 

 

(W)

 

 

 

 

62

33

500

124

121

80

50

1050

211

207

98

65

1600

305

300

5.3Adjusting for town gas

Proceed as described in point “5.2 Adjusting for bottled gas” but select the nozzles and adjust the primary air flow for town gas, as indicated in the table below and in point “5.4 Adjusting the primary air flow”..

Nominal

BurnerheatTown gas – G110 8 mbar capacity

(kW)

 

 

 

 

 

Nozzle diameter

 

Reduced heat capacity

 

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

Semi rapid (1)

 

1.7

 

165

 

500

 

 

 

 

 

 

 

Rapid (2)

 

2.9

 

230

 

1050

 

 

 

 

 

 

 

Ultra-Rapid (3)

 

4.2

 

300

 

1100

 

 

 

 

 

 

 

 

5.4Adjusting for natural gas

The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. To return the appliance to the condition required to use this type of gas, proceed as described in point “5.2 Adjusting for bottled gas” but select the nozzles and adjust the primary air flow for natural gas, as indicated in the table below and in point “5.5 Adjusting the primary air flow”.

Nominal

BurnerheatTown gas – G20 20 mbar capacity

(kW)

 

 

 

 

 

Nozzle diameter

 

Reduced heat capacity

 

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

 

Semi rapid (1)

 

1.7

 

92

 

500

 

 

 

 

 

 

 

 

 

Rapid (2)

 

2.9

 

123

 

1050

 

 

 

 

 

 

 

Ultra-Rapid (3)

 

4.2

 

145

 

1400

 

 

 

 

 

 

 

 

11

Page 9
Image 9