Smeg PTS723-3 manual Bottled gas connection, Room ventilation, Combustion gas discharge

Models: PTS723-3

1 16
Download 16 pages 50.78 Kb
Page 7
Image 7
4.1Bottled gas connection

Instructions for the Installer

4.1Bottled gas connection

Use a pressure regulator and make the connection to the gas cylinder in accordance with the relevant regulations. Make sure that the gas supply pressure is as stated in the table in point "5.2 Adjusting for bottled gas".

4.2Room ventilation

The appliance may only be installed in a permanently ventilated room as specified by the relevant regulations. The air flow into the room where the appliance is installed must be sufficient for proper gas combustion and room ventilation. The air intakes, protected by gratings, must be of suitable size (see relevant regulations) and located so that they cannot be even partially obstructed.

The kitchen must be kept properly ventilated to disperse the heat and humidity produced by cooking processes: in particular, a window should be opened or the speed of any fans increased after prolonged use.

4.3Combustion gas discharge

Combustion gases must be discharged by means of hoods connected to a flue with reliable natural draught, or a fan extraction system. An effective extraction system requires careful design by an authorised specialist, and must comply with the regulation distances and positions. After installation, the engineer must issue a certificate of compliance.

9

Page 7
Image 7
Smeg PTS723-3 manual Bottled gas connection, Room ventilation, Combustion gas discharge, Instructions for the Installer