Instructions for the installer

11.INSTALLING THE APPLIANCE

11.1Electrical connection

The I.D. plate with technical data, registration number and brand name is positioned visibly on the oven door frame.

The plate must not be removed.

The appliance must be connected to earth in compliance with electrical system safety regulations.

If a fixed connection is being used fit power line with an omnipolar circuit breaker with a contact opening gap equal to or greater than 3 mm, in an easily accessible position in proximity to the oven.

If a plug and socket connection is being used make sure that the plug and socket are compatible. Avoid use of adapters and shunts as these could cause overheating and risk of burns.

Operation at 220-240 V~: use a type

H05RR-F (3 x 1.5 mm2) or type

H05V2V2-F (3 x 1.5 mm2) three-wire cable.

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

WARNING: THE VALUES INDICATED ABOVE REFER TO THE CROSS- SECTION OF THE INTERNAL CONDUCTOR.

If the power supply lead has to be replaced, remove the rear casing by undoing the screws as shown below. The cross-section of the power lead

must be at least 1.5 mm2 (3 x 1.5 cable) and it must withstand temperatures up to 90°c (H05V2V2-F). Make sure that the cables follow the best possible route and use band clamps to fix them at the side of the cabinet, to avoid any contact with the oven.

42

Page 40
Image 40
Smeg SC112 manual Installing the Appliance, Electrical connection, Operation at 220-240 V~ use a type