Smeg SE900-5 manual Instructions for the installer, Installation, Electrical connection

Models: SE900 SE900-5

1 18
Download 18 pages 56.69 Kb
Page 4
Image 4
Instructions for the installer

Instructions for the installer

2 INSTALLATION

2.1Electrical connection

Check that mains voltage and power cable ratings are as per the indications provided on the label attached to the oven door frame.

This label must never be removed.

It is obligatory for the electrical system to be grounded according to the methods required by safety rules.

If a plug and socket connection is being used make sure that the plug and socket are compatible. Avoid use of adapters and shunts as these could cause overheating and risk of burns.

If a fixed connection is being used fit power line with an omnipolar circuit breaker with a contact opening gap equal to or greater than 3 mm in an easily accessible position in proximity to the oven.

Remove rear cover by loosening relevant screws to gain access to the terminal strip. Secure power cable to oven by means of the appropriate fitting.

If the power cable is replaced, the wire section on the new cable must not be less than 1.5 mm2 (3 x 1.5 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.

24

Page 4
Image 4
Smeg SE900-5 manual Instructions for the installer, Installation, Electrical connection, This label must never be removed