Resetting the Hardware
Resetting the Hardware
The EthernetBlaster communications cable restarts. When the status LED emits a steady green light, the EthernetBlaster has successfully reset and the new password is effective.
The EthernetBlaster communications cable reset button is located on the Ethernet port side of the hardware. See Figure
Figure
ETHERNET DC12V
Machine Reset | Paper clip |
Use a small pointed object such as a paper clip to press the machine reset button to restart and reset all values to the default factory settings. See Table
Table
Setting | Value |
|
|
Connection Type | DHCP |
|
|
Host name | acebXXXX (1) |
|
|
Domain name | Clear |
|
|
Timeserver Name/IP | Clear |
|
|
IP Address | 192.168.0.50 |
|
|
Subnet Mask | 255.255.255.0 |
|
|
Default Router | 192.168.0.1 |
|
|
DNS Server 1 | 0.0.0.0 |
|
|
DNS Server 2 | 0.0.0.0 |
|
|
Administrative Password | password |
|
|
Quartus II Remote Connection Password | password |
|
|
Note:
(1)The host name and MAC address are located on the label on the base of your cable. The last 4 digits of the MAC address represent the “XXXX” in the host name.
Altera Corporation | |