EthernetBlaster Communications Cable User Guide

Table 3–5. EthernetBlaster Cable DC Operating Conditions

Symbol

Parameter

Conditions

Min

Max

Unit

 

 

 

 

 

 

VIH

High-level input voltage

VCC(TARGET) < or = 3.3 V

VCC(TARGET) –0.2

 

V

 

High-level input voltage

VCC(TARGET) > 3.3 V

3.1

 

V

VIL

Low-level input voltage

 

 

 

0.15

V

VOH

5.0-V high-level output voltage

VCC(TARGET) = 4.5 V, IOH = 20 A

3.3

 

V

 

3.3-V high-level output voltage

VCC(TARGET) = 3.0 V, IOH = 20 A

2.0

 

V

 

 

 

 

 

 

 

2.5-V high-level output voltage

VCC(TARGET) = 2.375 V, IOH = 20 A

1.6

 

V

 

 

 

 

 

 

 

 

1.8-V high-level output voltage

VCC(TARGET) = 1.71

V, IOH = 20 A

1.15

 

V

 

1.5-V high-level output voltage

VCC(TARGET) = 1.43

V, IOH = 20 A

0.95

 

V

VOL

5.0-V low-level output voltage

VCC(TARGET) = 5.5 V, IOL = 1 mA

 

0.4

V

 

3.3-V low-level output voltage

VCC(TARGET) = 3.6 V, IOL = 1 mA

 

0.4

V

 

2.5-V low-level output voltage

VCC(TARGET) = 2.625 V, IOL = 1 mA

 

0.4

V

 

 

 

 

 

 

 

 

1.8-V low-level output voltage

VCC(TARGET) = 1.89

V, IOL = 1 mA

 

0.4

V

 

1.5-V low-level output voltage

VCC(TARGET) = 1.57

V, IOL = 1 mA

 

0.4

V

ICC(SYS)

Operating current (No Load)

Typical ICC(SYS) = 350mA @ VCC(SYS) = 12V

 

700

mA

References

For more information on configuration and in-system programmability (ISP), see the following sources:

AN 39: IEEE 1149.1 (JTAG) Boundary-Scan Testing in Altera Devices

AN 95: In-System Programmability in MAX Devices

“Configuring Cyclone FPGAs” chapter in the Cyclone Device Handbook

“Configuring Cyclone II Devices” chapter in the Cyclone II Device Handbook

Configuring Stratix II Devices” chapter in Volume 2 of the Stratix II Device Handbook

Configuring Stratix and Stratix GX Devices” chapter in the Stratix Device Handbook

“In-System Programmability Guidelines for MAX II Devices” chapter in the MAX II Device Handbook

Serial Configuration Devices Data Sheet

“Programming & Configuration” chapter in the Introduction to Quartus II manual

The Programming module of the Quartus II online tutorial

Refer to the following glossary definitions in Quartus II Help:

“EthernetBlaster Cable” (general description)

“Configuration scheme” (general description)

“Programming files” (general description)

Altera Corporation

3–5

December 2004

EthernetBlaster Communications Cable User Guide