Chapter 3. EthernetBlaster
Communications Cable
Specifications
This chapter provides comprehensive information about the EthernetBlaster communications cable, including the following:
■EthernetBlaster hardware connections
■Operating conditions
The EthernetBlaster cable connects to an Ethernet cable with a RJ45 jack to a
Depending on your connection (remote or direct), data is downloaded through the EthernetBlaster communications cable to the circuit board via the connections discussed in this section.
Voltage Requirements
The EthernetBlaster VCC(TARGET) pin must be connected to a specific voltage for the device being programmed. Connect
Table
Device Family | EthernetBlaster VCC Voltage Required |
|
|
MAX® II devices | As specified by VCCIO of Bank 1 |
MAX 7000S devices | 5 V |
|
|
MAX 7000AE and MAX 3000A devices | 3.3 V |
|
|
MAX 7000B devices | 2.5 V |
|
|
Stratix® II, Stratix GX, and Stratix devices | As specified by VCCSEL |
Cyclone™ II, Cyclone, APEX™ II, APEX 20K, and Mercury™ devices | As specified by VCCIO |
FLEX 10K®, FLEX® 8000, and FLEX 6000 devices | 5 V |
FLEX 10KE devices | 2.5 V |
|
|
FLEX 10KA and FLEX 6000A devices | 3.3 V |
|
|
EPC2 devices | 5 V or 3.3 V |
|
|
EPC4, EPC8, and EPC16 devices | 3.3 V |
|
|
EPCS1, EPCS4, EPCS16, and EPCS64 devices | 3.3 V |
|
|
Altera Corporation | |
December 2004 |
|