Chapter 3. EthernetBlaster

Communications Cable

Specifications

OverviewEthernetBlasterHardwareConnections

This chapter provides comprehensive information about the EthernetBlaster communications cable, including the following:

EthernetBlaster hardware connections

Operating conditions

The EthernetBlaster cable connects to an Ethernet cable with a RJ45 jack to a 10/100Base-T Ethernet hub/switch (via a straight 8-wire data cable) or a 10/100Base-T Ethernet port of a PC (via a crossover data cable).

Depending on your connection (remote or direct), data is downloaded through the EthernetBlaster communications cable to the circuit board via the connections discussed in this section.

Voltage Requirements

The EthernetBlaster VCC(TARGET) pin must be connected to a specific voltage for the device being programmed. Connect pull-up resistors to the same power supply as the EthernetBlaster VCC(TARGET). See Table 3–1.

Table 3–1. EthernetBlaster VCC(TARGET) Pin Voltage Requirements

Device Family

EthernetBlaster VCC Voltage Required

 

 

MAX® II devices

As specified by VCCIO of Bank 1

MAX 7000S devices

5 V

 

 

MAX 7000AE and MAX 3000A devices

3.3 V

 

 

MAX 7000B devices

2.5 V

 

 

Stratix® II, Stratix GX, and Stratix devices

As specified by VCCSEL

CycloneII, Cyclone, APEXII, APEX 20K, and Mercurydevices

As specified by VCCIO

FLEX 10K®, FLEX® 8000, and FLEX 6000 devices

5 V

FLEX 10KE devices

2.5 V

 

 

FLEX 10KA and FLEX 6000A devices

3.3 V

 

 

EPC2 devices

5 V or 3.3 V

 

 

EPC4, EPC8, and EPC16 devices

3.3 V

 

 

EPCS1, EPCS4, EPCS16, and EPCS64 devices

3.3 V

 

 