4-1 Installing an extra HDD for rebuilding
While the HDD with data is on the upper deck of the SR2000, start the computer. The computer will automatically detect the HDD on the lower deck of the SR2000. In case of abnormal operation, the buzzer will sound and the LCD will show the following:
Pri HDD OK
Sec HDD Fail
1.Insert a new HDD correctly on the lower deck of the SR2000. Screen will display and buzzer will sound in case of abnormal operation. If the HDD is properly set up, the LCD will show the following:
Pri HDD | OK |
Sec HDD | OK |
|
|
2. A few seconds later, the LCD will show:
Rebuilding …
Pri Sec XXX%
The data in the upper deck’s HDD will be rebuilt in the lower deck’s HDD.
XXX%: Percentage completed, ranging from 0~100.
3. When the rebuild is completed, LCD will show:
Pri HDD | OK |
Sec HDD | OK |
|
|
18 | SOHO RAID |