Connection

Functions assignable to P.Input1 to P.Input5 (input terminals)

Indication

Function

 

 

PLAY/PAUSE

The same function as HXbutton on the

 

main unit

 

 

PLAY

The same function as Hbutton on the

 

remote

 

 

PAUSE

The same function as Xbutton on the

 

remote

 

 

STOP

The same function as xbutton

 

 

AMS +

The same function as >button on the

 

remote

 

 

AMS –

The same function as .button on the

 

remote

 

 

FF

The same function as Mbutton

 

 

REW

The same function as mbutton

 

 

MARK

The same function as MARK button on the

 

remote

 

 

LOCATE

The same function as LOCATE button

 

 

EJECT

The same function as AEJECT button on

 

the main unit

 

 

Fader PLAY

Performs Fader Play (page 22)

 

 

1 Track PLAY

The same function as numeric buttons on

to 20 Track

the remote

PLAY

 

 

 

OFF

No operation

 

 

Functions assignable to P.Output1 to P.Output3 (output

 

terminals)

 

 

Indication

Function

PLAY

Grounding during playback on the player

 

 

PAUSE

Grounding during pause on the player

 

 

NO DISC

Grounding during no disc in the disc

 

compartment

 

 

OFF

Always floating

 

 

Do the procedure below to change the function of each terminal.

1 Press the MENU/EXIT button while the player is stopped.

“MENU Mode” appears in the display.

2 Rotate the AMS control until “Parallel” appears in the display, and then push the control.

If “Parallel” is already set to “User,” skip this step and step 3, and go to step 4.

3 Rotate the AMS control until “User” appears in the display, and then push the control.

4 Rotate the AMS control until the terminal that you want to assign function to (e.g., “P.Input1” or “P.Output2”) appears in the display, and then push the control.

5 Rotate the AMS control until the function that you want to assign to the terminal that you selected appears in the display, and then push the control. To assign functions to more terminals, repeat steps 4 and 5.

6 Press the MENU/EXIT button to complete the setting.

Notes

When “Preset” is selected for “Parallel,” you cannot select terminals or assign functions to them. To enable the assigning of functions to terminals, first select “User” for “Parallel.”

Doing the procedure above with “Preset” selected for “Parallel” allows you to check the factory setting for each terminal.

Electrical specifications for the

PARALLEL connector

Input terminals

Input system Make contact Input ON voltage Less than 0.5 V Input OFF voltage More than 3 V Opening terminal voltage

5 V

Input pulse width More than 100 msec Input standing voltage

–0.5 to +10 V

Output terminals

Output system

Open collector for NPN transistor

Remaining voltage at ON

 

Less than 0.5 V

Maximum current at ON

 

100 mA

Standing voltage

20 V

22